SAFETY
1.
Introduction
This manual contains all the information needed for the correct installation, use and maintenance of
your new
Standard Pump, Inc.
motor. It should be read and understood by all the personnel involved in
installation,
operating and servicing of the pump before it is started.
2.
Operator Qualification and Training
The personnel in charge of the installation, operation and maintenance of the pump unit we produce
must be
qualified and able to perform the operations described in this manual.
Standard Pump,
Inc.
shall not be held
responsible for the training level of personnel and for the fact that they are not fully
aware of the contents of this
manual.
3.
Safety Instructions
FOR YOUR OWN SAFETY:
BEFORE UNDERTAKING ANY SERVICE OPERATION ON YOUR MOTOR OR PUMP, PLEASE MAKE
SURE TO WEAR THE PROPER PROTECTIVE GEAR.
GENERAL DANGER
NEVER
use a plastic pump or an open, splash-proof, TEFC or non-ATEX motor when pumping or mixing
flammable or combustible material.
ALWAYS
use and store the pump and motor in an upright position.
DANGER: POWER SUPPLY
NEVER
perform any maintenance operation on the motor while it is running or before it has been disconnected
from the power supply. Avoid any possible hazard that might be caused by electric power.
ALWAYS
check the
electrical specifications on the motor data plate and make sure they correspond to the power supply to which it
will be connected.
ALWAYS
place motor in the OFF position prior to connecting the power source.
NEVER
immerse the
motor in liquid.
ALWAYS
use an ATEX Zone
1
approved plug and receptacle for ATEX motor models.
ALWAYS
use a UL/CSA Class I Division 1 Group D approved plug and receptacle for Hazardous Location
motor models.
4.
Noise Level
At normal operating conditions,
SP-430EX and SP-440EX
motors produce a sound level equal or less
than 81
dBA
at a distance of three feet (~ one meter).
5.
Modifications and Spare Parts
Any changes concerning the service of the motor as originally purchased, can be executed only after
written
approval from
Standard Pump,
Inc. It is recommended to use only genuine
Standard Pump,
Inc. spare parts
and approved accessories. The use of non-original spare parts or non-approved
accessories will void warranty
and removes any responsibility on our behalf for any damage caused to
people or things.
NEVER operate ATEX rated or Haz Loc rated motors outside their rated ambient temperature range of -20°C
to +40°C.
Warning: Explosion Hazard - Do not replace the cord on Explosion proof motor models. Replacing the cord will
invalidate the safety of the equipment. Return the motor back to the manufacturer for cord replacement. Do
not open or repair the flame-proof joints of Explosion proof motors. Contact the manufacturer for cord, fuse,
and circuit board replacement.
Static sparking can cause an explosion. Always follow NFPA 77 and CLC/TR 60079-32-1 guidelines for
control of static electricity and proper grounding methods when using ATEX and Hazardous Location motor
models. When operating in a hazardous area or pumping a hazardous fluid, the motor and entire pump system
must be grounded to prevent static discharge using appropriate grounding wires and connectors.
OIPM
-EXP-
0
8
18