5.3 USING THE NC-72 BATTERY CHARGER
1. Turn the transceiver off.
2. Insert the miniature plug on the end of
the
NC-72
Battery Charger cable into the
EXT DC
jack of the transceiver.
3. Plug the
NC-72
into a 120 VAC wall out-
let.
4. The indicator will glow red, indicating that
charging has begun.
5. When charging is completed, the red
indicator will change to green. Remove
the plug from the
EXT DC
jack when
charging has been accomplished.
6. Replace the rubber gasket in its place
to protect the inside of the transceiver
from the water.
We do not keep the water-proof while
opening the gasket.
5.4 FBA-23 BATTERY CASE
FBA-23
is a battery case that holds two alkaline batteries and is used with
the
HX460S
transceiver. Alkaline batteries can be used for transmission in
an emergency, but power output will only be
0.9 W
, and battery life will be
short.
1. Slide the batteries into the
FBA-23
with the Nega-
tive [–] side of the batteries touching the
spring
connections inside the
FBA-23
.
2. Insert the
FBA-23
into the battery compartment on
the back of the transceiver, then close the Battery
Pack Latch until it locks in place with a “click.”
Note:
The battery indicator on the transceiver is only
applicable to the
FNB-V75LI
rechargeable battery. Dis-
regard this indication when using alkaline batteries.