7. MENU
(
“SET”
)
MODE
The Setup Menu allows a number of the
HX407
operating parameters to be
custom-configured for your operating requirements.
The Menu Mode is easy to activate and set, using the following procedure:
1. Turn the transceiver off by rotating the
VOL
knob fully counter-clockwise.
2. Hold down the [P1] key, then turn on the transceiver while still holding
down the [P1] key.
3. The Menu item will scroll on the upper left corner of the display and its
current status or value will appear on the large display.
4. Press the or key to select the Menu item to be adjusted.
5. Press the [P1] key to enable adjustment of the selected Menu item. The
current status or value will blink.
6. Press the or key to select the desired status or value of the Menu
item.
7. After completing your adjustment, press the [P3] key to save the new
setting.
8. If you wish to change another Menu item, repeat steps 4 to 7 above.
9. Turn the transceiver off to exit to normal operation.
LAMP
Function
: Selects the Lamp illumination condition.
Available Values
: OFF / 2 / 5 / 7 / 10 / 15 (sec)
DIMMER
Function
: Selects the display brightness level.
Available Values
: OFF / 1 / 2 / 3 (level)
BEEP
Function
: Setting the Keypad beep.
Available Values
: oFF / Lo / Mi / Hi (level)
PRI-CH
Function
: Select the Priority Channel.
Available Values
: oFF / Ch No
SCAN TYPE
Function
: Selects the Scan Type.
Available Values
: PS (Pri-Scan) / MS (MEM-Scan)
Application for FCC / IC
FCC ID: K6630394X20
IC: 511B-30394X20