background image

- 9 -

The symbol of the crossed-out waste bin on the product, its packaging or the instruction manual means that the 

product should not be disposed of to normal waste bins. The user is obliged to hand over the used equipment to 

a designated collection point for proper processing

10. WARRANTY

The seller shall be liable under the warranty or guarantee.

In case of damage resulting from the formation of lime scale deposits in the device, it is not subject to repair under the 

warranty. The warranty does not cover damages caused by external forces such as lightning, changes in supply voltage, 

incorrect setting of the voltage value, supply from an inadequate power outlet, mechanical, thermal, chemical damages to the 

equipment and the defects caused by them.

Warranty exchange does not cover such elements as: light bulbs, rubber components, heating elements damaged by lime 

scale, screws and elements undergoing natural wear, e.g. burners, rubber seals and all kinds of mechanically damaged 

elements.

Summary of Contents for 880173

Page 1: ...880175 880176 880177 880400 880401 880402 880405 880406 880600 880601 880602 880603 880604 USER MANUAL Stalgast sp z o o ul Staniewicka 5 03 310 Warszawa tel 22 517 15 75 fax 22 517 15 77 www stalgast com email stalgast stalgast com v8 0 03 2018 ...

Page 2: ...cator 7 6 2 How to check the duration of the alarm and the minimum and maximum temperatures 7 6 3 Deleting a saved alarm recurring 7 6 4 How to view the setpoint 7 6 5 Changes in settings 7 6 6 Start manual defrost 7 6 7 Changing the value of the parameters 7 6 8 Locking the keyboard 7 6 9 Unlocking the keyboard 7 6 10 Continuous cycle 8 6 11 Alarms 8 7 CLEANING AND MAINTENANCE 8 8 PROCEDURE IN TH...

Page 3: ... never pull by the cord Secure the cable or its extension cord to ensure that no one pulls it from the socket by mistake and that no one trips over the cable Control the operation of the device during use It is prohibited for the device to be used by minors people with physical or mental disabilities and people with impaired mobility as well as persons without the appropriate experience and knowle...

Page 4: ...t off Measurement and control Flashing light Checking parameters entering the password Cooling control light Light on Cooling Light off Cooling stop Flashing light Cooling delay Defrost light Light on Defrosting Light off Defrosting stop 5 1 Main functions Interior temperature control Defrost control in accordance with the value set temperature difference value Defrost control defrosting when the ...

Page 5: ...word has been set to 0 the setting indicator lights up the display shows the F1 code from the menu the password is not confirmed and you must directly enter the menu mode to set the parameter If the keypad password has not been set to 0 the control light flashes and the display shows 00 press the button and to enter the password then press the SET button to confirm the password If the password is ...

Page 6: ...ally If the evaporator sensor has not been activated or if an error occurs the defrosting will be interrupted when the set defrosting time has elapsed or if the defrost is deactivated manually 5 6 Error messages Prompt Cause Effect E1 Chamber sensor error Have the maintenance service replace the chamber sensor After removing the fault the system will recalculate the compressor activation delay tim...

Page 7: ...econds the sensor value is displayed again 6 5 Changes in settings 1 Press the SET button for more than 2 seconds to change 2 The value of the settings will be displayed and the LED starts to flash 3 To change the settings press or for 10 seconds 4 In order to save new settings hold down the SET button for 10 seconds 6 6 Start manual defrost To start the defrosting process manually press and hold ...

Page 8: ...8 1 Starting the device in the case of going above the alarm temperature value The compressor starts working immediately after reconnecting the device to the power supply The display will show the HH alarm message until the preset temperature is reached Then the current temperature value inside the device will be displayed 8 2 Starting the device in the case of going below the alarm temperature va...

Page 9: ...ion of lime scale deposits in the device it is not subject to repair under the warranty The warranty does not cover damages caused by external forces such as lightning changes in supply voltage incorrect setting of the voltage value supply from an inadequate power outlet mechanical thermal chemical damages to the equipment and the defects caused by them Warranty exchange does not cover such elemen...

Reviews: