If no text is shown above the "MR" button on the
display panel, then the memory of the torque wrench
is full. (see Chapter "Memory is full", page 19).
If working through a define process, after the end
of a tightening process the next adjusting
parameter within the define process will be
selected. This applies to all operating modes.
After the last wrench process of the define
process the first wrench process will be selected.
Direct selection (SENSOTORK
®
713R only)
This function enables you to choose between torque
and angle modes. The "angle" mode does not differ
from the operating mode. The angular starting torque,
the extension length and the angle can be entered
directly for "angle" mode. A complete bolting operation
does not have to be programmed. Additionally
required parameters are taken over from the default
settings.
If you select an operating mode using direct
selection,
no values are stored
on completion of
a bolting operation.
To switch to direct selection, press the "L" and "R"
buttons simultaneously.
If you have activated direct selection, "direct" is shown
on the display. The selection menu is displayed:
Torque
Angle bolting operation.
Select the desired operating mode.
Press the "MR" button to confirm.
Angle
Enter the desired angular starting torque.
Press the "MR" button to confirm.
Enter the desired angle.
Press the "MR" button to confirm.
Now select the desired extension length.
Press the "MR" button to confirm.
An overview of the input values is displayed.
To confirm the display, press the "MR" button.
The torque wrench is now ready to use.
Resetting the torque wrench
To restart the torque wrench software, press the
"ML", "MR" and "O" buttons (the three arrowed
buttons pointing upwards) simultaneously.
If the software does not restart, remove the
batteries from the battery compartment of the
wrench.
Wait around 10 minutes, then replace the
batteries, taking care that the polarity indicated in
the battery compartment is observed.
Further settings
Presets
All presettings and tightening operations are
automatically taken over for the "Display" and
"Direct" modes, if no single tightening operations
have been inputted.
In the "presets" menu, the following settings can be
carried out.
To set up wrench processes, it is not really
necessary to undertake the following presets
In all settings, proceed as follows:
Select the menu item "presettings" with the "O" or
"U" buttons.
Confirm the selection with the "MR" button.
Select the desired menu item with the "O" or "U"
buttons.
Confirm the selection with the "MR" button.
Enter the desired text or values with the "O", "U",
"R" and "L" buttons.
To store the settings, confirm these with the "MR"
button.
Create or change the administrator's password
In order that data records for adjusting operations are
not inadvertently changed or altered by unauthorised
persons, the input functions of the wrench can be
protected by creating an administrator's password.
On delivery the wrench is not equipped with an
administrator's password. A maximum of sixteen
characters can be allocated.
If you have forgotten your administrator password,
it can be read out using the SENSOMASTER 4
software.
If you do not have the SENSOMASTER 4
software, send the torque wrench to
STAHLWILLE.
To change the administrator's password, proceed in
the same way as creating one (see Chapter "Presets"
page 18).
WARNING
Danger of severe injuries due to
excessively tight threaded
connections.
If the red light-emitting diode lights up,
immediately abort the bolting process.
Exchange the bolt for a new bolt.
ATTENTION
Without an administrator password, the torque
wrench can only be used to a limited extent.
Always store the administrator password in a
secure location.