7
WWW.HOTRONIX.COM
Operating Instructions
Before heat applying, set the target settings for the selected transfer material by:
•
Selecting a Preset (7.1), or
•
Manually entering target temperature, time and pressure.
Temperature and time are controlled automatically. Pressure must be set manually:
•
Position a cap on the lower heater (4.1)
•
Lower the cap hold down lever (4.2) to lock it in place
•
Enable “Target Temp” option in System Settings (11.1) to prevent the electromagnet
from locking down until Target Temperature is reached
•
Pull lift handle down and observe the pressure reading
•
Adjust the pressure by turning the Pressure Adjustment Knob
A visual Pressure Readout is located on the Home Screen. When the handle is locked
into the PRINT position, a pressure number between 0-9 will be displayed.
•
0 = No pressure
•
1 - 3 = Light Pressure
•
4 - 7 = Medium Pressure
•
8 - 9 = Heavy Pressure
WARNING
: Structural damage caused by excessive pressure is not covered under the limited warranty!
The lower heater alignment can be adjusted by loosening the knob to accomodate
different cap sizes (4.3).
Once your equipment has reached the designated temperature:
•
Position the cap and design (4.1)
•
Lower the cap hold down lever to lock cap into place (4.2)
•
Pull lift handle down and begin to heat apply
•
The automatic timing process will begin
•
The Home Screen will initiate a count down and lift the heat platen into the UP
position when the print cycle is complete (4.4).
Preparing to Print
4.2
4.1
4.3
4.4