Audible and visual signalling device

Series YL6S/2

Operating instructions

Additional languages r-stahl.com

DE
EN

FR

IT

ES

RU

NL

DK

SE

FI

PT

GR

PL

CZ
SK

HU

SL

RO

BG

LV

LT

EE

CH

KR

CN

 

Summary of Contents for YL6S/2 Series

Page 1: ...Audible and visual signalling device Series YL6S 2 Operating instructions Additional languages r stahl com DE EN FR IT ES RU NL DK SE FI PT GR PL CZ SK HU SL RO BG LV LT EE CH KR CN ...

Page 2: ...ty notes 6 3 1 Operating instructions storage 6 3 2 Personnel qualification 6 3 3 Safe use 6 3 4 Modifications and alterations 7 4 Function and device design 7 4 1 Function 7 4 2 Device design 8 5 Technical data 9 6 Transport and storage 15 7 Mounting and installation 16 7 1 Dimensions fastening dimensions 16 7 2 Mounting dismounting operating position 17 7 3 Installation 18 8 Commissioning 32 8 1...

Page 3: ...ndards and regulations For certificates and EU Declaration of Conformity see r stahl com The device has IECEx approval To view the certificate see IECEx homepage http iecex iec ch Further national certificates can be downloaded via the following link https r stahl com en global support downloads R STAHL Schaltgeräte GmbH Business Unit Lighting Signalling Nordstr 10 99427 Weimar Germany R STAHL Sch...

Page 4: ... CAUTION NOTICE Type and source of danger damage Consequences of danger Taking countermeasures to avoid the danger or damage Symbol Meaning Tips and recommendations on the use of the device General danger Danger due to explosive atmosphere DANGER Danger to persons Non compliance with the instruction results in severe or fatal injuries to persons WARNING Danger to persons Non compliance with the in...

Page 5: ...ol Meaning 05594E00 CE marking according to the current applicable directive 02198E00 Device certified for hazardous areas according to the marking 15649E00 Input 15648E00 Output 11048E00 Safety notes that must always be observed The corresponding data and or safety related instructions contained in the operating instructions must be followed for devices with this symbol 20690E00 Marking according...

Page 6: ... 14 Project engineering selection and construction of electrical systems IEC EN 60079 17 Electrical Installations Inspection and Maintenance IEC EN 60079 19 Equipment repair overhaul and reclamation 3 3 Safe use Before mounting Read and observe the safety notes in these operating instructions Ensure that the contents of these operating instructions are fully understood by the personnel in charge U...

Page 7: ... intended for use in explosive or harsh environments It is used in gas hazardous areas in Zones 1 and 2 as well as in dust hazardous areas in Zones 21 and 22 Mode of operation When activated the signalling device emits a visual and audible signal depending on the configuration and device version DANGER Explosion hazard due to modifications and alterations to the device Non compliance results in se...

Page 8: ...21 10 27 BA00 III en 00 DE EN FR IT ES RU NL DK SE FI PT GR PL CZ SK HU SL RO BG LV LT EE CH KR CN Audible and visual signalling device Series YL6S 2 4 2 Device design 23035E00 1 Horn cover 4 Flash flange 2 Enclosure 5 Cheese head screws 3 PCB 1 3 4 5 2 ...

Page 9: ...surface temperature tb T80 C T100 C Ambient temperature range 60 to 50 C 1 60 to 70 C 2 1 Loop in loop out wiring up to max 10 A 2 Loop in loop out wiring up to max 10 A connection line and cable entries with permissible operating temperature 90 C required Special conditions X Repair work on flameproof joints is only permissible in accordance with the values specified by the manufacturer The prote...

Page 10: ...5 Horn XENON 5J 650 12 5 Horn LED 700 12 5 In flash mode 1 500 12 5 Ambient temperature range Functional temperature range Temperature class T6 T4 Max surface temperature tb T80 C T100 C Ambient temperature range 60 to 50 C 1 60 to 70 C 2 1 Loop in loop out wiring up to max 10 A 2 Loop in loop out wiring up to max 10 A connection line and cable entries with permissible operating temperature 90 C r...

Page 11: ... IT ES RU NL DK SE FI PT GR PL CZ SK HU SL RO BG LV LT EE CH KR CN Audible and visual signalling device Series YL6S 2 Audible data Volume 110 dB A 1 m Calculated max range Inform 80 dB A 15 m Warn 85 dB A 8 m Alert 90 dB A 4 m Pole diagram 15288E00 22495E00 Technical data H ...

Page 12: ...6 m 46 m 8 m 10 m clear 86 m 111 m 19 m 25 m opal 74 m 94 m 16 m 21 m yellow 83 m 106 m 19 m 24 m magenta 19 m 25 m 4 m 6 m LED tower Inform Alert Function Flashing 1 Hz Blinking 1 Hz Flashing 1 Hz Blinking 1 Hz Colour red 52 m 67 m 12 m 15 m amber 87 m 111 m 19 m 25 m blue 47 m 61 m 11 m 14 m green 45 m 57 m 10 m 13 m clear 109 m 139 m 24 m 31 m opal 92 m 118 m 21 m 26 m yellow 104 m 133 m 23 m 3...

Page 13: ...hing 1 Hz Colour red 41 cd 67 cd 55 cd 90 cd 24 cd amber 96 cd 157 cd 151 cd 248 cd 76 cd blue 28 cd 47 cd 45 cd 74 cd 20 cd green 25 cd 42 cd 40 cd 66 cd 21 cd clear 150 cd 245 cd 236 cd 387 cd 136 cd opal 108 cd 178 cd 171 cd 280 cd 66 cd yellow 138 cd 226 cd 217 cd 356 cd 119 cd magenta 7 cd 12 cd 12 cd 19 cd 9 cd Luminous flux Type LED disc LED tower Function Continuous light Continuous light ...

Page 14: ...iagram XENON 22498E00 LED tower 22497E00 LED disc 22496E00 30 45 60 75 90 105 120 135 150 165 180 165 150 135 120 105 90 75 60 45 30 15 0 cd C0 C180 20 40 60 80 100 15 C90 C270 30 45 60 75 90 105 120 135 150 165 180 165 150 135 120 105 90 75 60 45 30 15 0 cd C0 C90 C180 C270 20 40 60 80 100 15 30 45 60 75 90 105 120 135 150 165 180 165 150 135 120 105 90 75 60 45 30 15 0 cd C0 C90 C180 C270 20 40 ...

Page 15: ... place no condensation free of vibrations Do not drop the device Technical data Flash energy XENON 5 J Signal function LED Continuous light maximum dimmed Flashing light single flash double flash triple flash 1 Hz 2 Hz 3 Hz Flashing light 1 Hz 1 5 Hz 2 Hz Rotating light 90rpm 120rpm 180rpm Chaos light XENON Flashing light single flash 1 Hz Mounting installation Connection type PUSH IN terminal Con...

Page 16: ...K HU SL RO BG LV LT EE CH KR CN Audible and visual signalling device Series YL6S 2 7 Mounting and installation 7 1 Dimensions fastening dimensions Dimensional drawings all dimensions in mm inch Subject to change 17151E00 403 15 87 Ø9 0 35 Ø 75 2 95 105 4 13 6 12 155 50 95 3 74 5 70 Ø 189 7 44 4 61 117 Ø145 178 50 7 03 ...

Page 17: ...arge generating environments The following processes activities should be avoided Accidental friction Particle flows DANGER Explosion hazard due to open drilled holes unused cable entries and cable glands Non compliance results in severe or fatal injuries Only use cable entries and stopping plugs that have been separately checked and certified in accordance with Directive 2014 34 EU ATEX and IECEx...

Page 18: ...ectrical lines see Technical data chapter using a suitable flameproof cable entry Close unused entries using certified flameproof stopping plugs 7 3 Installation The electrical installation and configuration of the device is performed in the following sequence Dismounting the device see chapter 7 3 1 Electrical connections see chapter 7 3 2 Configuration see chapter 7 3 3 Mounting the device see c...

Page 19: ...0 27 BA00 III en 00 Mounting and installation 19 DE EN FR IT ES RU NL DK SE FI PT GR PL CZ SK HU SL RO BG LV LT EE CH KR CN Audible and visual signalling device Series YL6S 2 23038E00 Remove the PCB 3 from the enclosure 2 3 1 2 ...

Page 20: ...otective measures Non compliance results in severe or fatal injuries Select suitable conductors to ensure that the maximum permissible conductor temperatures are not exceeded When using core end sleeves attach them using a suitable tool The conductor insulation must be touching the terminal Do not damage the conductor e g nicking when stripping it Finally check the conductor to ensure that it is s...

Page 21: ...le wire cross sections for the connection terminals see Technical data chapter Only such cable entries and stopping plugs may be installed that have been separately tested and certified according to Directive 2014 34 EU ATEX and IECEx CoC they must also comply technically with the standard version stated in the certificate Use electrical lines with a minimum length of 3 m or a cable gland with com...

Page 22: ...rn circuit board 22599E00 OPTIONS DIP switch DIP switch designation Function 12 OPTIONS General settings 13 SW1 Audible settings for sound level 1 14 SW2 Audible settings for sound level 2 1 2 3 4 5 ON ON Sound volume reduced by up to 18 dB A ON OFF Sound volume reduced by up to 12 dB A OFF ON Sound volume reduced by up to 6 dB A OFF OFF Max sound volume ON Reserved OFF Reserved ON ACTIVATION OF S...

Page 23: ...PTIONS General settings 13 SW1 Audible settings for sound level 1 14 SW2 Audible settings for sound level 2 15 SW3 Visual functions 16 SW4 General settings 2 1 2 3 4 5 ON ON Sound volume reduced by up to 18 dB A ON OFF Sound volume reduced by up to 12 dB A OFF ON Sound volume reduced by up to 6 dB A OFF OFF Max sound volume ON Reserved OFF Reserved ON ACTIVATION OF SOUND LEVELS 3 4 Control via A B...

Page 24: ...CTIVATION SOUND LEVELS 3 4 ACTIVATION A B SOUND Sound selection 0 0 0 0 Sound 1 SW1 0 0 1 0 Sound 2 SW2 0 0 0 1 Sound 1 SW1 0 0 1 1 Sound 2 SW2 0 1 0 0 Sound 1 SW1 0 1 1 0 Sound 2 SW2 0 1 0 1 Sound 3 SW1 0 1 1 1 Sound 4 SW1 1 0 1 0 0 Sound deactivated SW1 1 0 1 1 0 Sound deactivated SW2 1 0 1 0 1 Sound 1 SW1 1 0 1 1 1 Sound 2 SW2 1 2 3 4 5 ON Max LED current 2 OFF Max LED current ON LED disc OFF L...

Page 25: ... Flashing light 1 Hz Flashing light 2 Hz 0 1 0 1 0 Continuous light Rotating light 120 rpm Flashing light 1 Hz Flashing light 2 Hz 1 1 0 1 0 Continuous light Rotating light 180 rpm Flashing light 1 Hz Flashing light 2 Hz 0 0 1 1 0 Continuous light Rotating light 90 rpm Single flash 1 Hz Triple flash 1 Hz 1 0 1 1 0 Continuous light Rotating light 120 rpm Single flash 1 Hz Triple flash 1 Hz 0 1 1 1 ...

Page 26: ...ashing light 2 Hz Continuous light Flashing light 1 Hz Triple flash 1 Hz 0 0 1 0 0 Single flash 1 Hz Continuous light Double flash 1 Hz Triple flash 1 Hz 1 0 1 0 0 Double flash 1 Hz Continuous light Triple flash 1 Hz Triple flash 2 Hz 0 1 1 0 0 Triple flash 1 Hz Continuous light Triple flash 2 Hz Single flash 1 Hz 1 1 1 0 0 Single flash 2 Hz Continuous light Double flash 2 Hz Triple flash 2 Hz B R...

Page 27: ...larm level crossing 01 SW2 05 11 02 1 0 0 0 0 3100 Hz 2500 Hz 22572E00 Safety alarm 02 SW2 04 11 03 0 1 0 0 0 1000 Hz 800 Hz 22573E00 Increased urgency level crossing 03 SW2 05 11 04 1 1 0 0 0 3100 Hz 2500 Hz 22574E00 Security deterrent 04 SW2 02 11 05 0 0 1 0 0 554 Hz 440 Hz 22575E00 AFNOR France 05 SW2 01 14 06 1 0 1 0 0 470 Hz 430 Hz 22576E00 06 SW2 01 11 07 0 1 1 0 0 1000 Hz 800 Hz 22577E00 07...

Page 28: ...4 SW2 01 11 15 0 1 1 1 0 1000 Hz 22581E00 15 SW2 31 11 16 1 1 1 1 0 420 Hz 22582E00 AS2220 AS1610 AS1670 Australia 16 SW2 01 11 17 0 0 0 0 1 1000 Hz 22583E00 17 SW2 31 11 18 1 0 0 0 1 2500 Hz 22584E00 18 SW2 10 11 19 0 1 0 0 1 2500 Hz 22585E00 19 SW2 28 11 20 1 1 0 0 1 700 Hz 22586E00 Important message Sweden 20 SW2 08 11 21 0 0 1 0 1 1000 Hz 22587E00 21 SW2 28 11 Sou nd no SW1 SW2 Fre quency Soun...

Page 29: ...50 Hz 22592E00 26 SW2 07 11 27 0 1 0 1 1 1000 Hz 250 Hz 22593E00 27 SW2 31 15 28 1 1 0 1 1 1000 Hz 800 Hz 22594E00 ISO 8201 int evacuation alarm 28 SW2 08 11 29 0 0 1 1 1 1000 Hz 420 Hz 22595E00 29 SW2 01 11 30 1 0 1 1 1 1200 Hz 500 Hz 22596E00 Evacuation Netherlands 30 SW2 26 11 31 0 1 1 1 1 2500 Hz 500 Hz 22597E00 DIN 33404 fire alarm Germany 31 SW2 15 11 32 1 1 1 1 1 1200 Hz 250 Hz 22598E00 32 ...

Page 30: ...ce Series YL6S 2 7 3 4 Mounting the device 23035E00 1 Horn cover 4 Flash flange 2 Enclosure 5 Cheese head screws 3 PCB Screws and seals The cheese head screws are delivered with Nyltite seals Before mounting check the seals for damage Replace damaged seals Use seals a maximum of 5 times When using screws on a flat surface note the seal on the screw head see figure 15748E00 1 3 4 5 2 ...

Page 31: ...GR PL CZ SK HU SL RO BG LV LT EE CH KR CN Audible and visual signalling device Series YL6S 2 23039E00 Carefully insert the PCB 3 into the enclosure 2 23040E00 Connect the plug connector to the PCB 3 23041E00 Carefully place the flash flange on the enclosure and tighten the 6 cheese head screws 5 3 1 2 3 1 2 5 ...

Page 32: ... used the cable entries and stopping plugs have been securely tightened the electrical lines have been inserted correctly the connection has been performed correctly all screws and nuts have been tightened according to regulations the connection chamber is clean the device is not damaged there are no foreign objects inside the device the device is closed according to regulations The external conne...

Page 33: ...l Visual signal Control functions A B signal 22130E00 9 Operation The device is used to warn and alert by means of an audible signal a visual signal 9 1 Troubleshooting If the error cannot be eliminated using the specified procedures Contact R STAHL Schaltgeräte GmbH For rapid processing have the following information ready Type and serial number of the device Purchase information Error descriptio...

Page 34: ...ure has have cracks or other visible signs of damage Whether the seals have aged or been damaged Whether the permissible temperatures are complied with according to EN 60079 Whether the device is used as intended and functions properly Whether the connection lines are intact correctly connected and securely fixed Whether the protective conductor and equipotential bonding are connected Whether the ...

Page 35: ...haltgeräte GmbH refer to chapter 1 1 for the address 11 Cleaning Devices located in hazardous areas may only be cleaned with a damp cloth to avoid electrostatic charge When cleaning with a damp cloth use water or mild non abrasive non scratching cleaning agents Do not use abrasive cleaning agents or solvents Never clean the device with a strong water jet e g a pressure washer 12 Disposal Observe n...

Page 36: ...X ENIEC 60079 0 2018 EN 60079 1 2014 EN 60079 31 2014 Kennzeichnung marking marquage II2 G Ex db IIC T6 T4 Gb r r W II 2 D Ex tb NIC T 80 C T100 C Db v 0158 EU Baumusterprüfbescheinigung EU Type Examination Certificate Attestation d examen UE de type EPS 20 ATEX 1076 X Bureau Veritas Consumer Products Services Germany GmbH Businesspark A96 86842 Tuerkheim Germany Produktnormen nach Niederspannungs...