Summary of Contents for Tranberg TEF 4720

Page 1: ...17 R STAHL TRANBERG AS All rights reserved Installation and User Manual Navigation Light Control Panel TEF 4720 TEF 4722 TEF 4730 TEF 4732 Signal Light Control Panel TEF 4740 Version 2 2 R STAHL TRANBERG AS October 2017 ...

Page 2: ...0 Issued for use TRANBERG AS Technical dept October 2009 2 1 Issued for Use TRANBERG AS Technical dept October 2017 2 2 Issued for use R Stahl Tranberg AS Technical department R STAHL TRANBERG AS has made every effort to provide accurate information but makes no claims as to the accuracy or completeness of this information R STAHL TRANBERG AS disclaims liability for errors omissions misinterpretat...

Page 3: ...ON 2 08 AUXILIARY EQUIPMENT 96 CHAPTER III TEF 4730 104 SECTION 3 01 INTRODUCTION 105 SECTION 3 02 SYSTEM OVERVIEW 110 SECTION 3 03 FUNCTIONAL DESCRIPTION 113 SECTION 3 04 VOLTAGE COMPENSATION 130 SECTION 3 05 INSTALLATION 136 SECTION 3 06 TECHNICAL DATA 152 SECTION 3 07 SPARE PARTS 162 SECTION 3 08 AUXILIARY EQUIPMENT 176 CHAPTER IV TEF 4722 187 SECTION 4 01 INTRODUCTION 188 SECTION 4 02 SYSTEM O...

Page 4: ... 5 05 TECHNICAL DATA 284 SECTION 5 06 SPARE PARTS 294 CHAPTER VI TEF 4740 307 SECTION 6 01 INTRODUCTION 308 SECTION 6 02 SYSTEM OVERVIEW 312 SECTION 6 03 FUNCTIONAL DESCRIPTION 318 SECTION 6 04 INSTALLATION 332 SECTION 6 05 TECHNICAL DATA 342 SECTION 6 06 SPARE PARTS 352 CHAPTER VII ADDITIONAL INFORMATION 364 SECTION 7 01 TECHNICAL CLARIFICATIONS 366 ...

Page 5: ...f 24VAC DC main and emergency power supplies TEF 4722 is for controlling single tier navigation lights and for connection of 230VAC 115VAC main and emergency power supplies TEF 4730 is for controlling double tier navigation lights and for connection of 24VAC DC main and emergency power supplies TEF 4732 is for controlling double tier navigation lights and for connection of 230VAC 115VAC main and e...

Page 6: ...duction TEF 4720 is for controlling single tier navigation lights and for connection of 24VAC DC main and emergency power supplies Note All panels are custom made Refer to drawings for the specific system for overview and connections Section 2 02 System overview Section 2 03 Functional description Power supplies ...

Page 7: ...es The fuses are located in the outgoing terminal blocks Dimmer test button potential free alarm contact Indicator LED s for the outgoing circuits are dimmable Dimmer knob is located at the bottom left side LED s for power supplies are not dimmable Next to the dimmer knob a push button named test is located This button tests the function of indicator LED s and buzzer When pressed all LED s lights ...

Page 8: ...mers start up current when dimensioning fuse The panel handles both AC and DC current When DC current is connected make sure the phase is correct Navigation lights The panel is constructed for filament lamps 25 40W The panel can be modified for smaller loads Connect according to drawings Navigation lights should be grounded to the same potential as the panel 1 5mm2 cable is suitable in most cases ...

Page 9: ...20 Dimension WxHxD 8 circuits 144 x 240 x 150 mm 12 circuits 144 x 384 x 150 mm 16 circuits 144 x 384 x 150 mm Weight 8 circuits 3 5 kg 12 circuits 5 0 kg 16 circuits 5 5 kg Section 2 07 Spare parts Description Part No Main switch 50230082 Circuit switch 50230008 Test button 50230029 Dimmer potentiometer 50211023 Supply selector card P130 Ver2 4813 Alarm card P40 Ver2 50290089 Current sensing card...

Page 10: ...dary voltage outputs Used when supply voltage is 230VAC and or voltage compensation is required Part No Effect Primary voltage Secondary voltage 50860044 400VA 230V 50 60Hz 0V 22V 24V 26V 28V 30V 32V 50860028 500VA 230V 50 60Hz 0V 22V 24V 26V 28V 30V 32V 50860032 700VA 230V 50 60Hz 0V 22V 24V 26V 28V 30V 32V 50860081 1000VA 230V 50 60Hz 0V 22V 24V 26V 28V 30V 32V Transformers for other voltages de...

Page 11: ...EF 4730 Section 3 01 Introduction TEF 4730 is for controlling double tier navigation lights and for connection of 24VAC DC main and emergency power supplies Note All panels are custom made Refer to drawings for the specific system for overview and connections Section 3 02 System overview ...

Page 12: ...arm correct failure or switch circuit off Each output is fused in both poles The fuses are located in the outgoing terminal blocks Dimmer test button potential free alarm contact Indicator LED s for the outgoing circuits are dimmable Dimmer knob is located at the bottom left side LED s for power supplies are not dimmable Next to the dimmer knob a push button named test is located This button tests...

Page 13: ...n calculating total power If external transformers are used take into consideration transformers start up current when dimensioning fuse The panel handles both AC and DC current When DC current is connected make sure the phase is correct Navigation lights The panel is constructed for filament lamps 25 40W The panel can be modified for smaller loads Connect according to drawings Navigation lights s...

Page 14: ...circuits 192 x 240 x 150 mm 2x12 circuits 192 x 384 x 150 mm 2x16 circuits 192 x 384 x 150 mm Weight 2x8 circuits 4 5 kg 2x12 circuits 7 0 kg 2x16 circuits 7 5 kg Section 3 07 Spare parts Description Part No Main switch 50230082 Circuit switch 50230024 Test button 50230029 Dimmer potentiometer 50211023 Supply selector card P130 Ver2 4813 Alarm card P40 Ver2 50290089 Current sensing card P41 2935 L...

Page 15: ...ts Used when supply voltage is 230VAC and or voltage compensation is required Part No Effect Primary voltage Secondary voltage 50860044 400VA 230V 50 60Hz 0V 22V 24V 26V 28V 30V 32V 50860028 500VA 230V 50 60Hz 0V 22V 24V 26V 28V 30V 32V 50860032 700VA 230V 50 60Hz 0V 22V 24V 26V 28V 30V 32V 50860081 1000VA 230V 50 60Hz 0V 22V 24V 26V 28V 30V 32V Transformers for other voltages delivered on request...

Page 16: ...made Refer to drawings for the specific system for overview and connections Section 4 02 System overview Section 4 03 Functional description Power supplies The main switch operates both main and emergency supply Left position main supply middle position off and right position emergency supply Both power supplies are constantly monitored If a power supply is missing the alarm relay activates and a ...

Page 17: ...on off Each circuit is fused in both poles The fuses are located in the outgoing terminal blocks Dimmer test button potential free alarm contact Indicator LED s for the outgoing circuits are dimmable Dimmer knob is located at the bottom left side LED s for power supplies are not dimmable Next to the dimmer knob a push button named test is located This button tests the function of indicator LED s a...

Page 18: ...Main and emergency supply Max power consumption 9 circuits 780W 13 circuits 1150W 16 circuits 1400W Load Filament lamps 20 85W Outgoing fuses 4 0A Fast acting 5x20mm ceramic Compass safe distance 70cm Standard 40cm Standby steering emergency Ambient temp operating 0 to 55 C Enclosure class IP 20 Dimension WxHxD 144 x 384 x 160 mm Weight Max 5 5 kg Section 4 06 Spare parts Description Part No Main ...

Page 19: ...ll rights reserved Page 19 of 27 16 circuits 4816 LED card P93 9 circuits 4819 13 circuits 4820 16 circuits 4821 Transformer card P99 3425 Power relay 50231040 50231034 50231035 Fused terminal block 50281172 50281173 Fuse 4 0A 5x20mm 50232003 ...

Page 20: ...made Refer to drawings for the specific system for overview and connections Section 5 02 System overview Section 5 03 Functional description Power supplies The main switch operates both main and emergency supply Left position main supply middle position off and right position emergency supply Both power supplies are constantly monitored If a power supply is missing the alarm relay activates and a ...

Page 21: ...oing terminal blocks Dimmer test button potential free alarm contact Indicator LED s for the outgoing circuits are dimmable Dimmer knob is located at the bottom left side LED s for power supplies are not dimmable Next to the dimmer knob a push button named test is located This button tests the function of indicator LED s and buzzer When pressed all LED s lights up and buzzer is sounding Note The t...

Page 22: ... x 230V 115V 50 60Hz Main and emergency supply Max power consumption 2x9 circuits 780W 2x13 circuits 1150W 2x16 circuits 1400W Load Filament lamps 20 85W Outgoing fuses 4 0A Fast acting 5x20mm ceramic Compass safe distance 70cm Standard 40cm Standby steering emergency Ambient temp operating 0 to 55 C Enclosure class IP 20 Dimension WxHxD 192 x 384 x 160 mm Weight Max 6 5 kg Section 5 06 Spare part...

Page 23: ...ts 4818 13 circuits 4817 16 circuits 4816 LED card P93 9 circuits 4819 13 circuits 4820 16 circuits 4821 LED card P95 9 circuits 3435 13 circuits 3434 16 circuits 3382 Transformer card P99 3425 Power relay 50231040 50231034 50231035 Fused terminal block 50281172 50281173 Fuse 4 0A 5x20mm 50232003 ...

Page 24: ...apter VI TEF 4740 Section 6 01 Introduction TEF 4740 is constructed for controlling signal lights and for connection to 230VAC 115VAC power supply Note All panels are custom made Refer to drawings for the specific system for overview and connections Section 6 02 System overview ...

Page 25: ... outgoing circuits are dimmable Dimmer knob is located at the bottom left side LED s for power supplies are not dimmable Next to the dimmer knob a push button named test is located This button tests the function of indicator LED s and buzzer When pressed all LED s lights up and buzzer is sounding Note The test button does not check the status or functionality of the circuits or connected signal li...

Page 26: ...ng 5x20mm ceramic Compass safe distance 70cm Standard 40cm Standby steering emergency Ambient temp operating 0 to 55 C Enclosure class IP 20 Dimension WxHxD 144 x 384 x 160 mm Weight Max 5 5 kg Section 6 06 Spare parts Description Part No Main switch 50230023 Circuit switch 50230008 Test button 50230029 Dimmer potentiometer 50211028 Main card P91 Contact R Stahl Tranberg A S LED card P93 Contact R...

Page 27: ...rmation Section 7 01 Technical Clarifications Please contact R STAHL TRANBERG AS regarding clarifications Visiting address Strandsvingen 6 N 4032 Stavanger NORWAY Tel 47 51 57 89 00 Fax 47 51 57 89 50 Postal address Strandsvingen 6 N 4032 Stavanger NORWAY info stahl tranberg com www stahl tranberg com ...