background image

 

 

 

Installation Manual 

SERIES 300 

Operator Interfaces 

SERIES 400 Panel PC

 

SERIES 500 Thin Clients

 

 

Device platform EAGLE 

 

ET-xx6 / MT-xx6 

 

 

 

 
 
 
 

 
 
 

 

HW-Rev. ET-xx6-A-FX: 

03.00.12 

 

HW-Rev. ET-xx6-A-TX: 

03.00.22 

 

HW-Rev. ET-xx6-A-FX-BT: 

03.00.16 

 

HW-Rev. ET-xx6-A-TX-BT: 

03.00.26 

 

HW-Rev. ET-3x6-A-FX-BS: 

03.00.17 

 

HW-Rev. ET-3x6-A-TX-BS: 

03.00.27 

 
 
 

Installation Manual version: 

01.00.02 

 

Issue date: 

23.07.2018 

 

 

Summary of Contents for MT 6-A Series

Page 1: ...n Clients Device platform EAGLE ET xx6 MT xx6 HW Rev ET xx6 A FX 03 00 12 HW Rev ET xx6 A TX 03 00 22 HW Rev ET xx6 A FX BT 03 00 16 HW Rev ET xx6 A TX BT 03 00 26 HW Rev ET 3x6 A FX BS 03 00 17 HW Re...

Page 2: ...the publisher This document may be subject to change dates dimensions weight constructions drawings images Any warranty claims are limited to the right to demand amendments Liability for any damage th...

Page 3: ...w 6 5 Mounting 7 5 1 Mounting options 7 5 2 Recommended mounting type 8 5 3 Assembly notes 9 6 Tools 9 7 Mechanical Installation 9 7 1 Dimensions 10 7 2 Stand mounting 12 7 2 1 View 12 7 2 2 MPFL Stan...

Page 4: ...cquaint yourself with the multi touch functions of the operating system and the application Switch off the device for cleaning and maintenance Conductive liquids on the touch screen can result in inco...

Page 5: ...M_ET_MT xx6_en_V_01_00_02 docx 23 07 2018 Page 5 of 23 3 Enclosure types HSG xx6 VxA FR HSG xx6 VxA CFR with front door as standard with front door for cleanroom HSG xx6 VxA BD HSG xx6 VxA FRS with re...

Page 6: ...MT xx6 Versions mounted on stand or elbow Page 6 of 23 R STAHL HMI Systems GmbH IM_ET_MT xx6_en_V_01_00_02 docx 23 07 2018 4 Versions mounted on stand or elbow mounted upright on elbow mounted hanging...

Page 7: ...23 07 2018 Page 7 of 23 5 Mounting In regards of different applications and ambient conditions we recommend following installation types 5 1 Mounting options Mounted on stand Ceiling mounting Elbow up...

Page 8: ...n stand with without external keyboard No restriction Ceiling mount with MPFL stand with without external keyboard No restriction Mounted on elbow standing with without external keyboard No restrictio...

Page 9: ...at least 4 fastening points The type of wall fixing used must be suitable for the wall material 6 Tools 1x side cutter 1x wire stripping knife 1x wire stripper 1x spanner AF 10 1x spanner AF 13 1x spa...

Page 10: ...018 7 1 Dimensions Dimensions in mm HSG xx6 VxA FR Device A B C D E F G H I ET MT x06 ET MT x16 ET MT x36 625 516 190 720 304 400 78 34 270 ET MT x56 740 568 190 720 304 400 78 34 270 HSG xx6 VxA CFR...

Page 11: ...625 542 195 720 304 442 78 34 270 ET MT x56 740 568 195 720 304 442 78 34 270 HSG xx6 VxA FRS X Mounting tongue for wall mounting a Alternative mounting position of the mounting tongues Choose suitab...

Page 12: ...age 12 of 23 R STAHL HMI Systems GmbH IM_ET_MT xx6_en_V_01_00_02 docx 23 07 2018 7 2 Stand mounting 7 2 1 View 7 2 2 MPFL Stand Dimensions in mm Stand A B C D E F G H 1216 265 200 135 20 101 60 3 88 9...

Page 13: ...T_MT xx6_en_V_01_00_02 docx 23 07 2018 Page 13 of 23 7 2 3 Mounting Step by step Choose suitable mounting screws rawlplugs and bolts depending on the actual local requirements and possibilities Earthi...

Page 14: ...14 of 23 R STAHL HMI Systems GmbH IM_ET_MT xx6_en_V_01_00_02 docx 23 07 2018 A mounting holes for hanging mount B mounting holes for upright mount 3 enclosure operating device D mounting holes in the...

Page 15: ...Installation Manual ET MT xx6 Mechanical Installation R STAHL HMI Systems GmbH IM_ET_MT xx6_en_V_01_00_02 docx 23 07 2018 Page 15 of 23 C M6 Allen screw E mounting coupling F stand wall bracket or 4 5...

Page 16: ...Installation Manual ET MT xx6 Mechanical Installation Page 16 of 23 R STAHL HMI Systems GmbH IM_ET_MT xx6_en_V_01_00_02 docx 23 07 2018 6 7 tighten all 4 screws with a torque of 10 Nm...

Page 17: ...T xx6 Mechanical Installation R STAHL HMI Systems GmbH IM_ET_MT xx6_en_V_01_00_02 docx 23 07 2018 Page 17 of 23 1 Connection bolt for equipotential bonding Already wired to the multiple connection 2 i...

Page 18: ...Page 18 of 23 R STAHL HMI Systems GmbH IM_ET_MT xx6_en_V_01_00_02 docx 23 07 2018 FRS enclosure 1 Connection bolt for equipotential bonding Already wired in operator stations OS 2 Connection for equi...

Page 19: ...Electrical Installation 8 1 Connection of the X1 power supply Pin Signal name Description 1 24 VDC Power supply 24 VDC 2 3 Earth Power supply 0 VDC 4 8 2 Stand or enclosure equipotential bonding earth...

Page 20: ..._02 docx 23 07 2018 8 3 Ethernet interface TX FX 8 3 1 Ethernet interface copper connection TX X11 Yellow Orange White Blue Pin Signal Colour Note Connection 1 Tx Yellow twist 100Base TX interface 2 T...

Page 21: ...HMI Systems GmbH IM_ET_MT xx6_en_V_01_00_02 docx 23 07 2018 Page 21 of 23 8 3 2 Ethernet optical fiber interface FX X10 Multi mode optical fibre cable with 62 5 m core cross section and 125 m externa...

Page 22: ...notes Change of title on cover page Change of image on cover page Deletion of section Warnings as contents already contained in Operating Instructions Correction on description of vibration sinusoida...

Page 23: ...L HMI Systems GmbH Adolf Grimme Allee 8 D 50829 Cologne Phone switchboard 49 0 221 76 806 1000 hotline 5000 Fax 4100 E mail office stahl hmi de hotline support stahl hmi de www r stahl com www stahl h...

Reviews: