Installation Manual ET-/MT-xx6
Mounting
Page 8 of 23
R. STAHL HMI Systems GmbH / IM_ET_MT-xx6_en_V_01_00_02.docx / 23.07.2018
5.2
Recommended mounting type
The following recommended mounting types are the result of trying out many different types over
the years. Please follow these recommendations to ensure the optimum mounting type for your
device.
Before deciding on how to mount the device you need to check the vibration and shock conditions.
We cannot accept any responsibility if you select an unsuitable mounting type that results in
damage or failure of the device.
Conditions present at the
point of installation
Mounting / installation type
Recommendation
No vibration and no
shocks
Mounting on stand, with /
without external
keyboard
No restriction
Ceiling mount with
MPFL stand with /
without external
keyboard
No restriction
Mounted on elbow
standing with / without
external keyboard
No restriction
Mounted on elbow
hanging with / without
external keyboard
No restriction
Wall mounting
with / without external
keyboard
No restriction
Vibration sinusoidal
acc. to IEC 60068-2-6 and
DNV Certification No. 2.4:
5 … 13.2 Hz: ±1 mm
13.2 … 100 Hz: ±0.7 g
X, Y, Z axes
acc. to IEC 60068-2-6:
10 Hz, 1 g
450 Hz, 1 g
Change cycle 1 oct/min
Operating mode 1.2
X, Y, Z axes
Mounting on stand, with /
without external
keyboard
Not recommended
Ceiling mounting with
MPFL stand, with /
without external
keyboard
Not recommended
Mounted on elbow
standing with / without
external keyboard
Not recommended
Mounted on elbow
hanging, with / without
external keyboard
Not recommended
Wall mounting
with / without external
keyboard
No restriction