11.2.2
Connection Readerbox-054-AC-RS422
In contrast to the ReaderBox described in section 11.2.1 this section
describes a ReaderBox with AC connection and an RS-422 data
connection to the HMI unit.
Depending on the actual ReaderBox version (see order versions
listed in the "OI_ReaderBox" operating instructions), different
combinations of power supply and data connections are possible.
The ReaderBox cannot be supplied with power via the terminals of
the HMI units and therefore requires a separate power supply.
For the connection of the power supply of the ReaderBox, use a
suitable terminal box or connection box.
An RS-422 data connection to the ET-/MT-xx7 devices is not
possible as these HMI units have no RS-422 interface.
Overview:
NOTICE
NOTICE
5
6
NOTICE