![Stahl GUBox 8265/0 Series Operating Instructions Manual Download Page 41](http://html1.mh-extra.com/html/stahl/gubox-8265-0-series/gubox-8265-0-series_operating-instructions-manual_1357744041.webp)
143457 / 826560300010
2010-04-26·BA00·III·en·02
Maintenance
15
Light-metal Ex d enclosures /
flameproof enclosure 8265
10 Maintenance
10.1 Regular Maintenance Work
X
Consult the relevant regulations (e.g. IEC/EN 60079-17) to determine the type and
extent of inspections.
X
Plan the intervals so that any defects in the equipment which may be anticipated are
promptly detected.
To check as part of the maintenance schedule:
X
Check if the cables are clamped properly.
X
Inspect the device for signs of visible damage.
X
Compliance with the permitted temperatures in accordance with IEC/EN 60079-0.
X
Make sure that the device is used according to its designated use
10.2 Cleaning
X
Clean with a cloth, brush, vacuum cleaner or similar items.
WARNING
Danger from energised parts!
Z
Risk of severe injuries.
X
Before any maintenance work commences, disconnect the device from the
power supply.
X
Secure the device against unauthorised activation.
WARNING
Risk due to unauthorised work being performed on the device!
Z
Risk of injury and damage to equipment.
X
Assembly, installation, commissioning and servicing work must only be performed by
personnel who are both authorised and suitably trained for this purpose.
WARNING
Short-circuit in the circuit
Z
After multiple short circuits, the flameproof encapsulation is no longer
guaranteed.
X
After a short circuit, check the functionality of the device.
X
Replace the entire device if needed.
Summary of Contents for GUBox 8265/0 Series