Ammeters and voltmeters
Series 8402/6, Series 8403/6, Series 8404/6,
Series 8405/6, Series 8406/6, Series 8407/6
5.2
Installation
5.2.1 Conductor Connection
19973E00
Select suitable conductors that do not exceed the permitted heating temperature
within the enclosure.
Ensure that conductors have the specified cross-sections.
Guide the conductor insulation to the terminals
(for the conductor stripping length, see "Technical data").
Do not damage the conductor when stripping the insulation (e.g. by denting it).
Fit the core end sleeves properly using a suitable tool.
If the system is equipped with all possible terminals and live conductors, and the maximum
current load has been reached, ensure that the length of a conductor from the screw
connection to the terminal point does not exceed the diagonal planes of the enclosure.
Operation under difficult conditions, in particular on ships, requires additional
measures to be taken for correct installation, depending on the operating location.
Further information and instructions on this can be obtained from your regional sales
contact upon request.
DANGER! Risk of explosion due to improper installation!
Non-compliance may result in serious or even fatal injury.
Install the device carefully and only in accordance with the safety notes
("Safety" chapter).
The installation steps stated below must be carried out very precisely.
The necessary technical details/data on electrical installation can be found in the
following documents:
"Technical data" chapter in these operating instructions