Technical Data
Connection
Standard
:
Spring
clamp terminal 0.5 to 4 mm
2
Solid / Stranded
6-pole (2x L1, L2, L3, 2x L
I
, 2X N, 2x PE)
Special:
Screw-type terminals, 0.5 to 4 mm
2
finely and extra finely stranded, and 0.5 to 6 mm
2
solid
6-pole (2x L1, L2, L3, 2x LI, 2X N, 2x PE)
Through Wiring
Max, 16A
Switch-off
Standard
With separate Disconnect Switch for Lamp and Battery Compartments
Due to the faulty lamps
If lamp is faulty, power supply is automatically switched off by the electronic ballast.
Due to opening of the light fixture
Power to ballast is disconnected; switching element with 2 NC contacts in positive opening operation, they can only be switched on
again when the lamp cover and the central locking system are closed.
Light technical data
Lamps
Two-pin fluorescent lamps; 26 mm diameter; for holder G13
2 x 18 W; 2 x 36 W
Installation notes
Looping through of cables
there are cable entries on either side for looping through of connection cable.
Through wiring
Standard
Luminaires Without Through Wiring
Optional:
Luminaires are equipped with internal through wiring Incoming and outgoing leads, can be connected on the opposite sides.
Terminals: see Technical data:
Standard with
: 4mm
2
termination with 2.5 mm
2
wire,
Special with:
(Dv6 - 6 mm
2
termination with 2.5 mm
2
wire
Assembly
Recessed light fitting
Ceiling Mounting option is available with the Bracket.
Wall Mounting is also possible with a special mounting bracket.
6
Transport and Storage
6.1
General
•
Transport and storage are only permitted in the original packaging.
•
Store the device in a dry place (no condensation) and vibration-free.
•
Do not drop the device.
•
6.2
Batteries
•
Do not transport together with other materials!
•
Handle with care!
•
Store protected from fire, sources of dust, harmful gases and liquids!
•
Store in a dry and cool location!
Recommendation:
•
Store battery at an ambient temperature
of + 5 °C to + 25 °C and a relative humidity of 65 ± 5 %. The storage period is reduced of up to
one month if stored outside this temperature range.
•
To Avoid Deep-Discharge of the Battery,
disconnected the battery from the supply, through the connector provided in the battery
compartment, when the light fixture is not in use for a period longer than four weeks.