background image

 Instructions

 

 

1

 

 

 
 

 

Control board for electromechanical

 

gearmotors 

 

HERMES 

 

 
 
 
 
 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for HERMES

Page 1: ...Instructions 1 Control board for electromechanical gearmotors HERMES ...

Page 2: ...ce make sure that the power supply has been cut off The feeding cable can be connected only with feeders supplied with proper electric protection In particular make sure that the distance between the contacts is of at least 3 5 mm in order to avoid omnipolar disconnection from the grid Take into consideration the safety devices to be installed and the place where they should be positioned Always h...

Page 3: ... of gates with 1 or 2 shutters the movement is controlled by the encoder and there is no need to use limit switches 1 VAC 2 VAC 3 5 24 24 4 CONNETTORE MOLEX 6 APM1 10 ELS 11 COM1 12 LAMP 7 CHM1 8 APM2 9 CHM2 13 ENC1 20 FTO 21 STOP 22 COM 14 ENC2 19 APCH F2 10A 250V F1 0 63A 250V DL3 DL2 SW OFF 1 2 3 4 5 6 7 8 23 24 GND SIG M1 M2 J I H G F E D C B A RST ON CN1 15 ENC1 16 ENC1 17 18 ENC2 ENC2 DL1 CO...

Page 4: ...l 21 Electric contact normally closed by the Stop button 22 Common 23 Input antenna braided wire 24 Input antenna signal Connections radio card CONNECTOR MOLEX A Input antenna signal B Input antenna braided wire C Power supply receiver 12V dc negative pole D Power supply receiver 12V positive pole E Disconnected F Disconnected G Input receiver channel parallel to input of Open Close H Input receiv...

Page 5: ... obstruction during closing DL3 RED a Led which signals blockade of the gate the LED automatically switches off when the command Stop is activated RST Indicates a couple of Pin that short circuited for example by means of screwdriver allows RESET of the control box INPUTS OUTPUTS DEFINITIONS Input power supply from transformer 20V 10 Motors outputs 24V 100W the motor connected to the terminals 6 7...

Page 6: ...roceeds the operation of automatic learning of the shutter movements and bringing to automation the closing time The automatic learning phase is deactivated PROGRAMMING The programming of the central unit requires the following steps Manual opening of the gate Program SW 8 ON the blinking unit will emit a steady light to inform the user that the programming procedure has been started Press the Ope...

Page 7: ...f the semi automatic functioning is activated with SW 3 ON every Open Close command will cause the inversion of gate leaf movement both during the opening and closing phase 4 The Open Close command after the power supply is cut or reset by touching the two Pins marked as RST with the screwdriver point provokes first the complete opening of the gate and then the automatic closing up to the proper m...

Page 8: ...Instructions 8 Rev 0 03 06 Stagnoli s r l Via Mantova Traversa 1 105 A B 25017 Lonato Bs Italia Tel 39 030 9139511 Fax 39 030 91380 www stagnoli com ...