Instructions
4
ELECTRIC CONNECTIONS
1.
Neutral power supply from transformer (20Vac)
2.
Phase power supply from transformer (20Vac)
3.
Auxiliary output 24Vdc – 500mA (positive pole)
4.
Auxiliary output 24Vdc – 500 mA (negative pole )
5.
Connection of grounding
6.
Output 1° electric motor 24Vdc (opening)
7.
Output 1° electric motor 24Vdc (closing)
8.
Output 2° electric motor 24Vdc (opening)
9.
Output 2° electric motor 24Vdc (closing)
10.
Output of electromagnetic lock
11.
Common.
12.
Blinking logic output (24V – 15W max.)
13.
Signal input Encoder positioned on 1° motor.
14.
Signal input Encoder positioned on 2° motor.
15.
Power supply Encoder positioned on 1° motor (+)
16.
Power supply Encoder positioned on 1° motor (-)
17.
Power supply Encoder positioned on 2° motor (+)
18.
Power supply Encoder positioned on 1° motor (-)
19.
Electric contact normally opened by Open/Close Command.
20.
Electric contact normally closed by the photocell.
21.
Electric contact normally closed by the Stop button.
22.
Common.
23.
Input antenna ( braided wire).
24.
Input antenna (signal).
Connections radio card (CONNECTOR MOLEX)
A.
Input antenna (signal).
B.
Input antenna (braided wire)
C.
Power supply receiver: 12V dc (negative pole)
D.
Power supply receiver: 12V (positive pole)
E.
Disconnected
F.
Disconnected
G.
Input receiver channel (parallel to input of Open/Close)
H.
Input receiver channel (parallel to input of Open/Close)
I.
Disconnected
J.
Disconnected
•
N.C Contacts that are not used should be short circuited.
•
N.O Contacts that are not used, should be left.
•
Double insulated cables should be used when connected to low voltage devices.
•
In order to follow the regulations of “ Low Safety Voltage” rule (EN 60335-1), the single
insulated cables used for 230V supply should be equipped with additional insulation
of at least 1 mm, and should be at least 4 mm from those with low voltage.
•
The cables used for power supply of motors, should be of at least 2.5 mm
2
and the
length should not exceed 12 m;
•
IT IS COMPULSORY POSITIONING THE EARTH WIRE CONNECTION (TERMINAL
7)