3.2
Audio Connections
The XLR connectors (audio in and audio link) of the ES 10 are wired as follows:
Pin 1
= ground
Pin 2
= normal phase ( or “hot”)
Pin 3
= inverted phase (signal- or “cold”)
Always use high quality XLR connectors and shielded signal cables. Using the signal link
connectors, up to 30 ES 10s can be linked without a problem. If more than 30 ES 10s need to
be interconnected, a separate signal driver should be used.
The input stages are electronically balanced. To make optimum use of the balanced input stages
even in unbalanced situations, use balanced signal cables and connect pin 3 to pin 1 at the
output of the preceding apparatus. If this is not possible, connect pin 3 to pin 1 at the input of
the ES 10.
NEU
T
RIK
+
+
1
2
3
220-240 V
Cable Gauge (mm
2
)
1.5
2.5
4.0
6.0
10.0
16.0
No.
of
ES 10s
1
180
300
480
720
1200
1920
2
90
150
240
360
600
960
3
60
100
160
240
400
640
4
23
75
120
180
300
480
5
36
60
96
144
240
384
6
30
56
80
120
200
320
7
26
43
69
103
171
274
8
23
38
60
90
150
240
9
20
33
53
80
133
213
10
18
30
48
72
120
192
Table 3-3
Maximum cable length as a function of the cable gauge and the number of
ES 10s supplied through the cable.
CONNECT
IONS
stage accompany
R
ES 10 USER MANUAL
3-4