ST315B User Handbook
Page
5
Turning On
.
.
.
.
.
.
.
.
.
When turned on the ST315B performs a
display test by briefly illuminating all of
the display digits and all of the front pan-
el lamps.
The version number of the software embedded
within the ST315B is now displayed. If you ever
need technical support you will be asked for this
code together with the ST315B
’
s serial number.
Next displayed is the thermocouple type to which the ST315B is set. This
thermocouple type setting should match the type of thermocouple fitted to
the kiln and can be R, S, K or N type.
‘
R
’
type
thermo-
couple
‘
S
’
type
thermo-
couple
‘
K
’
type
thermo-
couple
‘
N
’
type
thermo-
couple
°C
°C/hr
hr.min
.
°C
°C/hr
hr.min
.
°C
°C/hr
hr.min
The final display should show the
kiln temperature (20°C shown here)
with the
‘
°C
’
indicator on. All oth-
er lamps should be off.
If the left
-
hand decimal point is on
then the keyboard is locked. This is
an anti
-
tamper feature. Press the
&
keys together & hold down for
5 seconds to unlock.
If any mimic panel lamps are on then
the ST315B is firing. Press the
START/STOP key to stop the firing.
During firing the right
-
hand decimal
point will light to show when the kiln
is heating.
T
urning On