Program Pause Facility
While firing press and hold down the
key for about 4 seconds. The
ST315B will pause the executing program. To un
-
pause the program
press and hold down the
key again for about 4 seconds. The effects of
pausing are as follows:
-
If paused during ramping the kiln temperature will be held (soaked)
in-
definitely
at the current kiln temperature. The ramp will continue when
un
-
pause is selected.
If paused during soaking then the soak time will be
extended indefinitely
.
The remainder of the soak period will be resumed when un
-
pause is se-
lected.
Segment advance (
key held down for about 4 seconds) can also be used
to terminate the pause. This will advance the segment and will immedi-
ately terminate a paused soak
-
advancing to the next segment (if any).
Changes made to the operation of the ST315B in this way are temporary
and are not stored.
°C
°C/hr
hr.min
As a warning during pause a double
beep is sounded every 10 seconds,
the display scrolls
for 5
seconds then shows the kiln temper-
ature for 5 seconds.
Ad
just
ing
Whil
e Firing
WARNING
-
PROGRAM PAUSE
The program pause facility should be used with care. Program execution is
suspended and the kiln will be held at its current temperature indefinitely.