background image

Dear Customer, thank you for purchasing a STAFER product. This manual describes the operations necessary for the correct 
installation of the V6RX.E

3

 / V7RX.E

3

 products. These tubular motors with electronic limit switches are suitable for handling the 

most popular types of rolling shutters. The motor's technical specifications are shown on the label affixed to the motor tube. 
These devices have not been designed for round-the-clock use. Any use of the product other than what is provided herein is 
improper and prohibited, and involves warranty voidance and liability disclaimer by the Manufacturer. The product must be 
assembled and installed only by a qualified technician. At the end of installation, all the manuals accompanying the product 
must be delivered to the end customer, who must keep them for future reference. Visit the site www.stafer.com to view updated 
documents, if any. 

The motor's technical features are shown on the label affixed to the motor tube. Before installing the motor, we recommend that 
you copy the technical data (including the full product name) and store them in a safe place. These data could be useful at the 
time of maintenance or technical assistance. Additional features common to the V6RX.E

3

/V7RX.E

3

 motor family.

Power supply 

: 230 Vac 50 Hz

Idle consumption 

: < 0,5W

Minimum V6RX.E roller diameter  : 50 x 1.5 mm
Minimum V7RXE roller diameter   : 60 x 1.5 mm

Protection grade 

 : IP44

Insulation class 

 : H

Maximum limit switch revolutions  : 

Revolving operating time 

: 4 minutes

Radio frequency                                 : 433.42 MHz
Storable portable transmitters       

: 40

Storable sun/wind radio sensors:  

: 1

01. TECHNICAL SPECIFICATIONS

Protecting the environment is everyone's duty! STAFER uses recyclable packaging materials. Dispose of materials in proper 
containers, in compliance with laws in force in your location. If you are an installer and use a large number of motors, ask your 
dealer or the Company about receiving motors in “honeycomb pads”, an environmentally friendly choice that limits clutter and 
waste by significantly reducing the amount of packaging materials. This product may contain substances that are polluting for 
the environment and dangerous to health. At the end of the product life cycle, carefully comply with the appropriate waste 
disposal rules. It is hazardous, and thus strictly forbidden to dispose of the product in the domestic waste.

Let's protect the environment

01. Technical specifications of motors and remote controls
02. Warnings
03. Rating tables and motor components
04. Electrical connection
05. Some information on motor operation
06. Movement control functions
07. Installation via command buttons
08. Installation via remote control
09. Add/delete a radio device
10. Upper limit switch fine-tuning
11. Lower limit switch fine-tuning
12. Button logic
13. Third limit switch (preferred position)
14. Third limit switch inversion
15. Sun/wind anemometer
16. Radio test for anemometer
17. Shutter release
18. Orientation (micro movements)
19. Reset to factory values

Index

It is advisable to avoid using radio systems in areas with strong interference (for example, near police stations, airports, ports, 
banks, etc.). A technical inspection is in any case advisable before installing any radio system in order to identify sources of 
interference. Radio systems can be used where possible disturbances or malfunctioning of the transmitter or the receiver do 
not cause a risk factor, or if the risk factor is cancelled by suitable safety systems. The presence of radio devices operating on 
the same transmission frequency (433.42 MHz) can interfere with the radio receiver of the device and thus reduce the range of 
the system and limit the functionality of the entire system.

Notes on radio systems

01

USER AND MAINTENANCE MANUAL 

Ø 45 mm and Ø55 mm tubular motors with electronic limit switch and radio receiver

V6

RX.E

3

 - V7

RX.E

3

version 1.0

recycled paper

Compatible STAFER remote controls

595.T.X1.00

(1 channel)

596.T.X1.00 

(1 channel) 

596.T.X5.00 

(15 channels)

595.M.X1.00 

(1 channel)

www.stafer.com

VIDEO TUTORIAL 

Summary of Contents for V6RX.E3

Page 1: ...ng motors in honeycomb pads an environmentally friendly choice that limits clutter and waste by significantly reducing the amount of packaging materials This product may contain substances that are polluting for the environment and dangerous to health At the end of the product life cycle carefully comply with the appropriate waste disposal rules It is hazardous and thus strictly forbidden to dispo...

Page 2: ...he event of overheating The motor returns to normal operation when its temperature drops below the safety limit normally from 5 to 10 minutes The motor must be installed in such a way that it does not come into contact with liquids and in any case in a location protected from the elements The antenna cable is subjected to mains voltage It is forbidden and dangerous to tamper with the antenna cable...

Page 3: ...ond pulse is used d When the contacts are open the home automation control unit must close a contact up or down for less than 0 5 seconds to stop the motor typically a pulse of 0 2 seconds is used Rules for the home automation control unit to comply with to control the motors with MAN PRESENT operated push buttons a The home automation control unit MUSTNOTmeasure the current absorbed by the button...

Page 4: ...te closing In this mode it is also possible through the specific function paragraph 17 to activate and adjust the time to release the shutter immediately after cassette closing 05 SOME INFORMATION ON MOTOR OPERATION If you want to better adjust the position of the limit switches using the buttons proceed as described in paragraphs 10 or 11 Sometimes it is possible that once the procedure has been ...

Page 5: ...p After you reach the desired position press STOP 3 times 3 x3 After 2 seconds the motor moves down and up O After 2 seconds the motor moves down and up END P SHOULD THE LIMIT SWITCHES BE ADJUSTED BETTER OR DO THEY NEED FINE TUNING See paragraphs 10 and 11 page 6 3 After 2 seconds the motor replicates the movements G After 2 seconds the motor moves up down After 2 seconds the motor moves up and do...

Page 6: ...fly press DOWN once The motor moves to the lower limit switch 05 Adjust the new position with UP DOWN 06 Once positioned wait 5 seconds The motor completes 1 up down movement Limit switch setting stored 11 2 USING COMMAND BUTTONS Wait for 5 seconds 12 3 9 6 1 x DOWN ON 3 x DOWN 3 x UP Advanced Info 12 BUTTON LOGIC 12 1 USING THE REMOTE CONTROL Item 596 The command buttons can work in PULSE logic o...

Page 7: ...arantee the integrity of the rolling shutter under all conditions but a means to reduce the probability that the rolling shutter will be damaged by adverse weather events The buttons must be pressed shortly max 1 second between two pressures The buttons must be pressed shortly max 1 second between two pressures 16 SUN WIND ANEMOMETER RADIO TEST As soon as a sun wind radio anemometer is stored in t...

Page 8: ...efly and quickly press DOWN 7 times The motor shows the current value from 1 to 5 movements 05 Briefly press UP as many times as the setting you want from 1 to 5 06 After 5 seconds the motor signals the new setting from 1 to 5 movements To adjust 01 Briefly press a button then immediately press and hold it 18 3 USING COMMAND BUTTONS Allows you moving the motor in short strokes Useful function for ...

Page 9: ...y authorised by STAFER the device must be used exclusively with transmitters produced by STAFER STAFER cannot be considered responsible for damage caused by improper incorrect or unreasonable uses SIMPLIFIED DECLARATION OF CONFORMITY The manufacturer STAFER s p a declares that the product complies with Directives 2014 53 EU 2014 35 EU and 2014 30 EU 19 2 USING REMOTE CONTROL Item 595 01 Bring the ...

Reviews: