09
19. FACTORY VALUE RESET
19.1 USING REMOTE CONTROL Item 596
01. If possible, bring motor to an intermediate position.
02. Cut off the power supply.
03. Connect as shown in the diagram on the side.
04. Power up the motor. The motor signals 6 up/down movements.
06. Cut off the power supply.
07. Restore the connections. (REFER to diagram in paragraph 4)
08. Install the motor again (see paragraph 5 or 6 of this manual).
19.4 USING THE POWER CABLES
01. Bring the motor to the intermediate position.
02. Press MENU. The motor moves up/down. Display shows: - - .
03. Press
UP twice
and
DOWN 9 times
, 29 appears on the display.
04. Press
STOP
, the motor makes 6 movements up and down. Wait until it stops.
05. Press
UP twice
until the motor signals that the reset has been completed
(1 double movement).
06. Press
MENU
to exit.
07. Install the motor again (see section 6 or 7 of this manual).
L (phase)
N (neutral)
motor
cable
grey
brown
blue
yellow/green
black
ELECTRICAL
DIAGRAM FOR RESET
All rights reserved.
STAFER S.p.a. - via Malpighi, 9 - 48018 Faenza (RA) ITALY
Tel. (+39) 0546.624811 - Fax (+39) 0546.623141 - www.stafer.com
All products and technical specifications given in this document are subject to variation without prior notice.
Unless previously and specifically authorised by STAFER, the device must be used exclusively with transmitters produced by STAFER.
STAFER cannot be considered responsible for damage caused by improper, incorrect or unreasonable uses.
SIMPLIFIED DECLARATION OF CONFORMITY
The manufacturer STAFER s.p.a. declares that the product complies with Directives 2014/53/EU, 2014/35/EU, and 2014/30/EU.
19.2 USING REMOTE CONTROL Item 595
01. Bring the motor to the intermediate position.
02. Press
3 times on PROG
*. The motor shows: up/down.
03. Press
twice on UP
and
9 times on DOWN
.
04. Press
STOP
, the motor makes 6 movements up and down.
Wait until it stops.
05. Press
UP
twice
until the motor signals that the reset has been completed
(1 double movement).
06. Press
PROG 3
times
to exit.
07. Install the motor again (see section 6 or 7 of this manual).
(*) The buttons must be pressed shortly, max 1 second between two pressures.
16.1 UTILIZZANDO IL RADIOCOMANDO
19.3 USING THE WALL-MOUNTED BUTTON (IF ANY)
01. USING THE REMOTE CONTROL Bring the motor to the intermediate position.
02. Turn off the power, wait a few seconds, then power up again.
03. Within 15 seconds, briefly and quickly press
UP 3 times
and
DOWN 3 times
.
The motor moves up/down.
04. Within 15 seconds, briefly and quickly press
UP twice
and
DOWN 9 times
.
The motor performs 6 up/down movements.
05. At the end of the movements, briefly press
UP twice
.
06. The motor signals that the reset has been carried out (1 double movement).