TECH 500 DP

5

en

4. Display elements

Elements for visual guidance

Acoustic guidance: activated 

See chapter 5.1

Units of measurement:  °, %, mm/m, in/ft

See chapter 7.4

Reference: activated

See chapter 7.4

Key lock: activated

(15)

(16)

(17)

(18)

(19)

(20)

(21)

(22)

22

20

17

18

21

19

Summary of Contents for TECH 500 DP

Page 1: ...How true pro s measure TECH 500 DP User manual...

Page 2: ...ns 7 6 1 Visual guidance 7 6 2 Acoustic guidance 8 6 3 Automatic display inversion 8 6 4 Setting the MODE unit of measurement 9 6 5 Locking the measurement with HOLD 9 6 6 Freely selectable zero posit...

Page 3: ...or operation Carrying case 2 Safety information Read the safety instructions and operating instructions through carefully Keep these operating instructions in a safe place and include them when passin...

Page 4: ...h M4 groove stones e g Bosch Rexroth or square nut in accordance with DIN 557 V shape for aligning on round surfaces Rare earth magnet Buttons On Off Units of measurement mm m in ft Calibration and se...

Page 5: ...elements Elements for visual guidance Acoustic guidance activated See chapter 5 1 Units of measurement mm m in ft See chapter 7 4 Reference activated See chapter 7 4 Key lock activated 15 16 17 18 19...

Page 6: ...If you do not intend to use the unit for an extended period remove the batteries 5 1 Inserting batteries battery replacement 5 Commissioning After switching on with the ON OFF button an automatic tes...

Page 7: ...ce In the range of 15 to the horizontal 0 or to the vertical 90 arrows show which way to turn the digital protractor to reach 0 or 90 The 2 centre display bars indicate the precise position at which 0...

Page 8: ...hey are always easy to read The acoustic guidance is activated deactivated using the Loudspeaker button The tone sequence speeds up as the 0 or 90 position is approached in a range of 2 A change in th...

Page 9: ...ps mm m Display in 1 mm m steps in ft decimal Display in 0 01 in ft steps in ft fraction Display in 1 8 in ft steps The set unit of measurement is retained after the unit is switched off The current m...

Page 10: ...conds by briefly pressing the REF button B The reference angle is deleted by pressing and holding 3 sec the REF button The activated button lock must be released before deleting the angle Switching of...

Page 11: ...OFF Pressing the Lighting and Acoustic guidance buttons at the same time allows the automatic switch off time to be changed from 1 8 of an hour approx 7 5 minutes to 2 hours The set switch off time i...

Page 12: ...sible e g table with the display side facing the user Determine the measurement Step 2 Turn the unit by 180 in the same position Step 3 The rear of the unit is now facing the user Compare the new meas...

Page 13: ...ton CAL flashes in the display CAL2 display Calibration step 1 successfully completed Step 2 Turn the unit by 180 in the same position Step 3 The rear of the unit is now facing the user The second cal...

Page 14: ...adjustment B The sensor can only be adjusted if the two black bars appear on the display in the range of 0 and 90 C CAL and the planes still to be adjusted flash alternately while the sensor is being...

Page 15: ...Adjusting the sensor Step 1 Simultaneously press the MODE and CAL buttons Step 2 Hold the unit in plane 1 Press the CAL button If the plane has been adjusted successfully it is permanently indicated...

Page 16: ...o plane 2 Press the CAL button If the plane has been adjusted successfully it is permanently indicated in the display Step 4 Turn the unit by 90 to plane 3 Press the CAL button If the plane has been a...

Page 17: ...indicated in the display 7 4 Error messages Display Cal temperature The sensor must be adjusted if the temperature or Cal symbols are indicated in the display Display Err The unit must not be moved o...

Page 18: ...1 5 V alkaline Mignon AA LR6 MN1500 Battery life 150 hours Operating temperature range 10 C to 5o C 14 F to 122 F Storage temperature range 20 C to 65 C 4 F to 149 F Housing material Aluminium PC ABS...

Page 19: ...tralia Asia Africa STABILA Inc 332 Industrial Drive South Elgin IL 60177 800 869 7460 custservice Stabila com STABILA Messger te Gustav Ullrich GmbH P O Box 13 40 D 76851 Annweiler Landauer Str 45 D 7...