User manual

Summary of Contents for TECH 196

Page 1: ...User manual...

Page 2: ...ions 7 6 1 Visual guidance 7 6 2 Acoustic guidance 8 6 3 Automatic display inversion 8 6 4 Setting the MODE unit of measurement 9 6 5 Locking the measurement with HOLD 9 6 6 Freely selectable zero pos...

Page 3: ...can obtain advice by telephone 49 63 46 3 09 0 1 800 869 7460 U S and Canada Equipment and functions Vertical vial s for vertical levelling in reverse position too Horizontal vial for horizontal leve...

Page 4: ...ials vertical and horizontal Removable shock absorbing end caps Anti slip stopper Rare earth magnet 196 M Buttons On Off Units of measurement mm m in ft Calibration and sensor adjustment HOLD locking...

Page 5: ...nce Acoustic guidance activated Battery low see chapter 5 1 Units of measurement mm m in ft Significant temperature change see chapter 9 Reference activated Sensor calibration necessary see chapter 9...

Page 6: ...t intend to use the unit for some time 2x 1 5V Alkaline AA LR6 Mignon MN 1500 5 1 Inserting batteries battery replacement 5 Commissioning 5 2 Switching the unit on After switching on with the ON OFF b...

Page 7: ...ance In the range of 15 to the horizontal 0 or to the vertical 90 arrows show which way to turn the digital protractor to reach 0 or 90 The 2 centre display bars indicate the precise position at which...

Page 8: ...nce speeds up as the 0 or 90 position is approached in a range of 2 A change in the pitch indicates that these positions have been exceeded A continuous tone confirms the precise point at which 0 or 9...

Page 9: ...steps in ft decimal Display in 0 01 in ft steps in ft fraction Display in 1 8 in ft steps The set unit of measurement is retained after the unit is switched off 6 5 Locking the measurement with HOLD...

Page 10: ...reference angle is deleted by pressing and holding 3 sec the REF button The activated button lock must be released before deleting the angle Switching off The automatic switch off function The zero po...

Page 11: ...to OFF Pressing the Lighting and Acoustic guidance buttons at the same time allows the automatic switch off time to be changed from 1 8 of an hour approx 7 5 minutes to 2 hours The set switch off time...

Page 12: ...suring surfaces of the electronic spirit level should be positioned precisely for all measurement work If positioned at too great an angle the tilt function prevents incorrect measurements The display...

Page 13: ...temperature Step 1 Switch on the electronic spirit level Use the vial to accura tely align the unit to a wall for example until the vial bubble is in the middle between the vial rings Step 2 Wait 10...

Page 14: ...he vertical vial 2 Hold the electronic spirit level in this position and press the CAL button The CAL display shows calibration mode 3 Calibration starts when the CAL button is pressed again Newly cal...

Page 15: ...ibrated in 4 measuring posi tions consecutively turning 90 180 each time A All 4 planes are adjusted during the sensor adjustment B The sensor can only be adjusted if the two black bars appear on the...

Page 16: ...accurately against a wall and press the CAL button to confirm Step 1 must be performed with the vial This ensures that the spirit level the horizontal vial and the sensor are synchronised with each o...

Page 17: ...d The electronic spirit level is aligned horizontally using the arrows displayed The 2 centre display bars indicate the precise position at which the horizontal is reached Confirm with the CAL button...

Page 18: ...d aligned vertically using the arrows displayed The 2 centre display bars indicate the precise position at which the vertical is reached Confirm with the CAL button The flashing segment indicates the...

Page 19: ...ronic spirit level is turned 180 and aligned vertically using the arrows displayed The 2 centre display bars indicate the precise position at which the vertical is reached Confirm with the CAL button...

Page 20: ...ust be adjusted if the temperature or Cal symbols are indicated in the display Display Err The unit must not be moved or subjected to vibrations during the calibration sensor adjustment This can lead...

Page 21: ...level in normal position 0 5 mm m 0 029 in reverse position 0 5 mm m 0 029 Batteries 2 x 1 5 V alkaline Mignon AA LR6 MN1500 Operating life 150 hours Operating temperature range 10 C to 50 C 14 F to...

Page 22: ...tralia Asia Africa STABILA Inc 332 Industrial Drive South Elgin IL 60177 800 869 7460 custservice Stabila com STABILA Messger te Gustav Ullrich GmbH P O Box 13 40 D 76851 Annweiler Landauer Str 45 D 7...