![background image](http://html1.mh-extra.com/html/stabila/tech-196-2-electronic-series/tech-196-2-electronic-series_operating-instructions-manual_1356622005.webp)
“0”. It is easier to find “0” over and over and this will help
reduce errors. Being able to Reference any angle or slope as
“0”, also enables you to have your electronic level “tell” you
when you have reached your precise angle or slope with an even
tone as it does for level and plumb.
o
Tip: (Foreman function) With this function, a foreman or lead-
man can set the level to work at specific angle or slope to
ensure that their crew is doing the work at hand properly.
o
How to Use:
Adjust your electronic level to the exact angle or
slope that you wish to reference. Push the REF button once and
the LCD screen will then read 0.0 at your angle or slope. As a
built in safety mechanism, the digits on the screen will
continuously blink in this function in order to alert the user
that the measurement is no longer at zero being level. While in
the Reference mode, if you wish to be reminded what angle or
slope you are referring to, push the button once. The screen
will display your angle or slope for 2 seconds and then return to
Reference mode. To return your electronic level back to
calibrated level again, simply push the REF button for 3 seconds
then release, or power your level off, then on again.
New reference value (REF)
For some applications it might be useful to select a reference other than 0°.
With the REF button, any inclination can be selected as 0°.
When the REF button is pressed the last value is set as 0°. All subsequent measurements
are indicated in reference to the selected inclination.
During this mode the display values will blink slowly to indicate that the selected
reference is not 0°.
Press the REF button briefly: the stored reference angle is shown in the display briefly.
Press the REF button longer: the reference angle is deleted and the unit switches back to
standard mode.
If the inclinometer is switched off the reference angle is deleted (except for KEYLOCK
mode). When switched on again, the inclinometer will start with the calibrated values.
In the REF mode the "auto-off time" is increased to 2 hours.
www.
GlobalTestSupply
.com
Find Quality Products Online at: