background image

12

Appendix

Stabila LD 400

D

GB

SLO

F

I

E

P

NL

N

FIN

DK

TK

CZ

PL

S

HR

H

SK

J

LV

LT

KOR

RUS

CHN

EST

GR

RO

Disposal

CAUTION:

Flat batteries must not be disposed of with 

household waste. Care for the environment and take 
them to the collection points provided in accordance 
with national or local regulations.

The product must not be disposed with 
household waste.
Dispose of the product appropriately in 
accordance with the national regulations in 
force in your country.

Adhere to the national and country specific regula-
tions.

All right reserved for changes (drawings, descriptions 
and technical specifications).

Summary of Contents for LD 400

Page 1: ......

Page 2: ......

Page 3: ......

Page 4: ...l finan cial and environmental damage Important paragraphs which must be adhered to in practice as they enable the product to be used in a technically correct and efficient manner Intended Use Permitted uses Measuring distances Computing functions e g areas and volumes Adverse uses Using the instrument without instructions Using outside the stated limits Deactivation of safety systems and removal ...

Page 5: ...s They are also responsible for the effecti veness of these safety concepts in combination with the Stabila equipment Responsibilities of the person in charge of the instrument WARNING The person responsible for the instrument must ensure that the equipment is used in accor dance with the instructions This person is also accountable for the deployment of personnel and for their training and for th...

Page 6: ...e used for a long time remove the batteries as a protection against corrosion Operation Measuring Conditions Range Range is limited to 60 m At night or dusk and if the target is in shadow the measuring range without target plate is increased Use a target plate to increase the measurement range during daylight or if the target has poor reflec tion properties Target Surfaces CAUTION Measuring errors...

Page 7: ...e will occur Switching on off 1x briefly the instrument and the laser are swit ched on The display shows the battery symbol until the next button is pressed Pressing this button for longer switches the instrument off The instrument switches off automatically after three minutes of inactivity Setting the instrument Press long until the desired unit is displayed Possible units CLEAR Key 1x briefly t...

Page 8: ...efe rence is set 2x long the measurements are taken from the unfolded end piece until a new measuring refe rence is set See drawing F Measuring Single Distance Measurement 1x briefly the laser is activated 1x briefly a distance measurement is taken The result is displayed immediately Continuous measurement Distances can be measured with this function 1x long a beep is sounded A continuous measurem...

Page 9: ...rement is displayed in the summary row the individually measured values are displayed in intermediate lines 1 and 2 Adding and subtracting areas Calling up the area function and measuring areas Press 1x or 2x 1x briefly takes first distance measurement e g length 1x briefly takes second distance measurement e g width The result of the second area measurement flashes 1x briefly confirms the additio...

Page 10: ... function Indirect measurement determining a distance using 2 auxilliary measurements See drawing G 1x briefly the symbol is displayed The distance to be measured flashes in the symbol 1x briefly takes a measurement of the distance The second distance to be measured flashes in the symbol 1x briefly takes a measurement of the hori zontal distance The result of the function is displayed in the summa...

Page 11: ...xt appro priate stake out point is displayed When approaching a stakeout point to less than 0 10 m the instrument starts to beep When the point is reached the beep sound changes and inter mediate line 1 starts to flash 1x briefly distance measurement is interrupted and the instrument switches back to individual distance measuring mode Historical memory 1x briefly the symbol and the last measured v...

Page 12: ...splay Notices All display notices are either displayed with or Error The following errors can be corrected Cause Correction 204 Calculation error Repeat procedure 252 Temperature too high Let device cool down 253 Temperature too low Warm device up 255 Received signal too weak time for a measurement too long Use a target plate 256 Received signal too strong Use target plate gray side 257 Faulty mea...

Page 13: ...to function smoothly in an environment where electromagnetic radiation and electrostatic discharges are present and without causing electromagnetic interference to other equipment WARNING The Stabila LD 400 conforms to the most strin gent requirements of the relevant standards and regulations Yet the possibility of the product causing interfe rence in other equipment cannot be fully excluded Range...

Page 14: ...ardous Precautions Do not look directly into the beam with optical aids CAUTION Looking into the laser beam may be hazardous to the eyes Precautions Do not stare into beam Do not look into the laser beam Make sure the laser is aimed above or below eye level particularly with fixed installations in machines etc Labelling For the position of the type plate see drawing J Care Wipe off dirt with a dam...

Page 15: ...onment and take them to the collection points provided in accordance with national or local regulations The product must not be disposed with household waste Dispose of the product appropriately in accordance with the national regulations in force in your country Adhere to the national and country specific regula tions All right reserved for changes drawings descriptions and technical specificatio...

Reviews: