10
Appendix
Stabila LD 400
D
GB
SLO
F
I
E
P
NL
N
FIN
DK
TK
CZ
PL
S
HR
H
SK
J
LV
LT
KOR
RUS
CHN
EST
GR
RO
Technical Specifications
* Use a target plate to increase the measurement range
during daylight or if the target has poor reflection properties!
** in favourable conditions (good target surface properties,
room temperature) up to 10 m. In unfavourable conditions,
such as intense sunshine, poorly reflecting target surface or
high temperature variations, the deviation over distances
above 10 m can increase by ± 0.15 mm/m.
Electromagnetic Compatibility
(EMC)
The term "electromagnetic compatibility" is taken to
mean the capability of the product to function
smoothly in an environment where electromagnetic
radiation and electrostatic discharges are present,
and without causing electromagnetic interference to
other equipment.
WARNING
The Stabila LD 400 conforms to the most strin-
gent requirements of the relevant standards and
regulations.
Yet. the possibility of the product causing interfe-
rence in other equipment cannot be fully excluded.
Range
0.05 m to 60 m*
Measuring accuracy (2
σ
)
typically ± 1.5 mm**
Smallest unit displayed
1 mm
Laser class
2
Laser type
635 nm, < 1 mW
Protection against
splashes and dust
IP 54, dust-proof,
splash-proof
Autom. power off:
Laser
Instrument
after 60 s
after 180 s
Illumination
9
Folding out endpiece
9
Battery life,
Type 2 x AAA
up to
5 000 measurements
Dimension
113 x 50 x 25 mm
Weight
110 g
Temperature range:
Storage
Operation
-25°C to +70°C
0°C to +40°C