background image

Main applications:

Unscrew the telescopic poles from the base unit.
Assemble the telescopic poles for a room height of up to
2.75 metres using the threaded sleeves.
Secure the instrument firmly between the floor and cei-
ling using the spring unit, securing plate and base unit.
Position the laser. To secure in position, turn the locking
lever until it is tight.

Opening the set.
Remove the parts.
Erect the tripod with the required height.
Position the laser.

B1

B2

B3

C1

C2

C3

Commissioning 

The instrument is switched on with the on/off switch (4).
Vertical and horizontal lines will appear after switching on.
The laser will automatically level itself.

The laser will flash if the inclination is
too great.

I. 
II. 

III.

IV.

I. 
II. 
III.
IV.

Levelling at variable heights up to 2.75 metres

Levelling with tripod function

NB:

In Class II laser equipment, your eyes
are protected from accidental, short-
term exposure to the laser beam by the
lid-closing reflex and/or the reflex reac-
tion to turn one's head. This equipment
can therefore be used without additio-
nal protective measures. Nevertheless,
you should not look directly into the
laser beam. 

The laser goggles enclosed with these units
are not safety goggles. They are designed
to make the laser light easier to see.

Do not let the unit
fall into children's
hands!

EN 60825-1 : 03 10

LAX-50.qxd  04.01.2007  15:13  Seite 15

Summary of Contents for LAX 50

Page 1: ...Laser LAX 50 Operating instructions en...

Page 2: ...1 3 1 2 1 2 3 2 1 2 3 2 75 m B1 B2 B3 C1 C2 C3...

Page 3: ...A 2 3 1 4 12 6 5 13 14 15 7 8 10 11 9...

Page 4: ...2m 1 mm 2m D1 E1 D2 D3 E2 E3...

Page 5: ...s 5m 16 E4 F1 F2 F3 F4 F5 ft 3 2 1 5 mm X 5m 1 5 mm...

Page 6: ...cted laser lines provide exact alignment working The different parts of this set enable a tripod or a long support pole to be constructed to suspend the instrument between the floor and the ceiling We...

Page 7: ...rizontal lines will appear after switching on The laser will automatically level itself The laser will flash if the inclination is too great I II III IV I II III IV Levelling at variable heights up to...

Page 8: ...levell ling range Checking the calibration You must create a reference to perform this test Fasten a plumbline near to the wall The laser unit should now be set up in front of this reference mark dis...

Page 9: ...mm 10 0 mm 15 0 mm Maximum permissible figure S Now move the unit directly in front of wall B Set the unit s height so that the laser dot s height matches that of point 2 8 1 Horizontal checking Line...

Page 10: ...too much is outside the self levelling range the laser cannot level itself automatically laser beam f fl la as sh hi in ng g Recycling programme for our EU customers In accordance with the WEEE regula...

Page 11: ...ns Care and maintenance Like any precision instrument handle the LAX 50 crossed line laser carefully and cautiously Laser type Technical data Self levelling range Output Levelling accuracy Batteries O...

Reviews: