Wiring
The SuperFlo
®
VS Variable Speed Pump controller must be wired according to the locally adopted version of the
National Electrical Code. A licensed, qualified electrician should complete the wiring for this product.
The controller is designed to operate with 220-240 Vrms, single phase power.
The pump is designed to handle either a bare wire connection or a quick disconnect connection. The quick
disconnect tab is 6.35 mm and will handle any commonly available mating connectors. For a direct wire
connection, the wire insulation should be stripped to a length of approximately 8 mm The terminal block is capable
of handling solid or stranded wire up to 4.0 mm² in size. The screw for the mains connections should be properly
tightened to a torque value of 1.15 Nm.
Pin #
Wire Color
Description
L1
Blue
Hot 1
L2
Red/White
Hot 2
Ground screw Green/Yellow
Earth
Figure 5: Main Connection Diagram
Table 3: Main Connections
Power should be turned off when installing, servicing, or repairing electrical components.
Observe all warning notices posted on the existing equipment, pump, and in these installation
instructions.
English