OPERATING THE PUMP

Keypad Overview

 

1. 

STEP 1 (Set Schedule)    

è 

DURATION and SPEED

2. 

STEP 2 (Set Schedule)    

è 

DURATION and SPEED

3. 

STEP 3 (Set Schedule)    

è 

DURATION and SPEED

4. 

OVERRIDE (Settings)      

è 

DURATION and SPEED

5. START
6. STOP

Set a Schedule

Set the DURATION and SPEED for the SuperFlo

®

 VS Variable 

Speed Pump using the keys on the User Interface. The schedule is 

based on a 24-hour schedule and will repeat each day of the week.  

       

 

 

The highest speed rating for the pump is 3450 RPM 

and the lowest is 600 RPM.  Unless a new user-defined 

schedule is entered, the pump will operate based on the 

following factory default schedule:

Table 1: Factory default schedule

Button

Duration

(In Hours)

Speed

(In RPM)

STEP 1

4

2600

STEP 2

4

2100

STEP 3

4

1600

OVERRIDE

2

3100

Schedule Tables

Use the tables below to record a personalized 

operating schedule.  Recording the planned 

schedule in the table below will make the 

programming process easier and will help the 

user remember the custom settings in case of 

inadvertent loss of schedule.  The user interface 

will not allow the user to program an overlap 

between different STEPs of the schedule.  The 

STEP currently being set will always take priority 

over any previous settings.  In the event a user 

attempts to program with a combined duration 

greater than 24 hours, the current STEP setting 

will be retained whereas the other two STEP 

settings will be cleared to zero hours requiring 

the user to reset them.  Prior to beginning the 

actual programming process, it is advisable 

for the user to review the planned schedule as 

outlined in chart form to ensure the cumulative 

duration is not greater than 24 hours and no 

overlaps exist.  It is always a good idea to double 

check your programmed settings for accuracy 

once you have completed the programming 

process.

Setup #1

Step 1

Step 2

Step 3

Duration

 

 

Speed

 

Table 2: Custom Schedule

Setup #2

Step 1

Step 2

Step 3

Duration

 

 

Speed

 

If power is connected to the pump motor, pressing any of the following buttons 
referred to in this section could result in the motor starting. Failure to recognize this 

could result in personal injury or damage to equipment.

If power is connected to the pump motor, pressing any of the following buttons 
referred to in this section could result in the motor starting. Failure to recognize this 

could result in personal injury or damage to equipment.

English          

Summary of Contents for S5P1R-VS

Page 1: ...NG BEDIENUNGSANLEITUNG GUIDE DE L INSTALLATION GUIA DE INSTALACION GUIDE ALL INSTALLAZIONE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WATER SOLUTIONS P INSB...

Page 2: ...and Functions Quick Start Guide Factory Default Schedule User Defined Schedule Control Panel Overview Navigation Operating the Pump Keypad Overview Setting a Schedule Schedule Tables Pump Operation f...

Page 3: ...THE OWNER S MANUAL MUST BE LEFT WITH THE POOL OWNER SUCTION ENTRAPMENT HAZARD STAY OFF THE MAIN DRAIN AND AWAY FROM ALL SUCTION OUTLETS F THIS PUMP PRODUCES HIGH LEVELS OF SUCTION AND CREATES A STRONG...

Page 4: ...pecific application and properly installed Fitting a non return valve after the pump on the installation will prevent the impeller from unwinding and is strongly recommended Pumps improperly sized or...

Page 5: ...40 years Compact rugged and easy to maintain the SuperFlo VS pump will deliver years of reliable service SuperFlo VS Pump PUMP OVERVIEW Pump Controller Features Simple user interface Motor design red...

Page 6: ...ine the most satisfactory settings as dictated by the conditions In most cases setting the pump at the lowest speed for the longest duration is the best strategy to minimize energy consumption However...

Page 7: ...view X Power START FAULT STEP1 STEP2 STEP3 OVERRIDE SETTING SETTING BARGRAPH X Step1 X X X Step2 X X X Step3 X X X Override X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X LED Indi...

Page 8: ...P 1 key again to change the SPEED setting The SPEED setting LED will illuminate The bar graph will show default SPEED for STEP 1 see figure 2 3 Press UP or DOWN arrows to change the SPEED 4 Press any...

Page 9: ...he pump is capable of operating Pressing the stop button will turn off the START LED and stop the motor if running If power is connected to the SuperFlo VSVariable Speed Pump motor pressing any of the...

Page 10: ...er to program an overlap between different STEPs of the schedule The STEP currently being set will always take priority over any previous settings In the event a user attempts to program with a combin...

Page 11: ...finitely until the user presses the STOP key Note Pressing a STEP key other than for the STEP currently running will cause an immediate transition to the newly selected STEP The pump will continue wit...

Page 12: ...der to change the OVERRIDE settings if the duration is set to 0 HRS Schedule Advance The Schedule Advance mode allows the user to press the START button at one time of the day with the 24 hour schedul...

Page 13: ...r more than three 3 seconds The START and OVERRIDE buttons will blink once every second indicating that the time out feature is enabled These LEDs will stop blinking once this feature is cancelled Tem...

Page 14: ...d to factory defaults Priming The pump will always run the PRIMING sequence when starting from the OFF state except when starting in OVERRIDE The factory Prime settings are 2850 RPM for three 3 minute...

Page 15: ...National Electrical Code and all applicable local codes and ordinances When in doubt use a heavier gauge larger diameter wire Heavier gauge will allow the motor to run cooler and more efficient 4 Be s...

Page 16: ...35 mm and will handle any commonly available mating connectors For a direct wire connection the wire insulation should be stripped to a length of approximately 8 mm The terminal block is capable of h...

Page 17: ...g this area External Supply Range 18 30V AC 24V AC 20 9 30V DC 12 24V DC 20 Figure 6 Wiring Diagram for Automation Control System Inputs UI DIGITAL INPUT CONNECTOR J202 STEP 1 pin 1 STEP 2 pin 2 STEP...

Page 18: ...oncept can be applied to a solar system or any other type of control system Note There is no schedule for automation system inputs The timing for each speed is controlled directly by the inputs Note T...

Page 19: ...of the pump pot Note It is important to keep the lid O ring clean and well lubricated 8 Reinstall the lid by placing the lid on the pot Be sure the lid O ring is properly placed Seat the clamp and lid...

Page 20: ...Inordertoavoidthepossibilityofpersonalinjury makesurethesuctionanddischargevalvesare open and strainer pot temperature is cool to touch then open with extreme caution Besurenottoscratchormarthepolishe...

Page 21: ...valve close the valve The system should now be free of air and recirculating water to and from the pool Pump Reassembly 1 When installing the replacement seal into the seal plate use soapy water to we...

Page 22: ...ot drawing air Turn off electrical power to the pump Disassemble see page 20 Pump Disassembly Clean debris from impeller If debris cannot be removed complete the following steps 1 Remove left hand thr...

Page 23: ...oblem Possible Cause Corrective Action Pump runs without flow Impeller is loose Air leak Clogged or restricted plumbing Check that pump is spinning by looking at fan on back of SuperFloVS Variable Spe...

Page 24: ...r is running then the FAULT LED will illuminate During the FAULT condition the bar graph LEDs on the interface will turn OFF However the power LED start LED active STEP LED will remain illuminated 3 W...