MAINTENANCE

To prevent airlocking, make sure air bleed hole is not plugged. To clear it, un-
plug pump and clean hole with a short piece of wire.

Risk of electrical shock if motor is incorrectly assembled. Do

not have it repaired locally. Do not attempt to replace cord.

Motor is not designed for field maintenance. It is filled with special 
dielectric oil and sealed. Attempting to open or work on motor can cause
shock hazard and will void warranty.

If motor needs repair, call Sta-Rite Customer Service at 1-800-752-0183.

TROUBLESHOOTING

1.

Motor fails to run

A. Check fuses, etc. to be sure there is current at outlet.

B. Check GFCI in outlet for tripping. GFCI protects against dangerous 

current leaks to ground. If GFCI has tripped and will not reset, DO
NOT USE PUMP until problem is repaired.

C. If motor runs for a short time and cuts out:

1. Turn power to pump OFF; unplug pump.
2. Remove base plate and check to see that impeller turns freely.
3. If pump still does not operate after this preliminary check, take it to

a qualified motor repair facility.

1.

Pump runs but does not pump water

A. Discharge outlet too high above pump. Lower hose or pipe outlet.

B. Pump is airlocked. Clean air bleed hole (see Figure 4, Page 4).

C. Suction Baseplate may be plugged.

1. Turn power to pump OFF; unplug pump.
2. Remove baseplate and clean holes around edge.
3. Reinstall baseplate.
4. Put pump in water before starting.
5. Plug in pump; turn power ON.

Summary of Contents for PCD-10B

Page 1: ...d companies in the United States and or other countries Unless noted names and brands of others that may be used in this document are not used to indicate an affilitaion or endorsement betweent the pr...

Page 2: ...uit can cause dangerous electrical shock hazard DO NOT allow anyone including pump operator in the water while pump is standing in water and connected to power source whether pump is running or not DO...

Page 3: ...switch rod After the pin is in place pull gently on the rod to make sure it is retained by the pin 4795 0105 1 2 FIGURE 1 3 4 5 4801 0105 6076 0709 FIGURE 2 Step 3 Attach the bracket to the switch wit...

Page 4: ...harge hose or piping to pump discharge with 1 1 4 NPT fittings Use discharge hose or pipe of 1 1 4 diameter or larger Make sure that pump outlet is not restricted Step 9 Make sure air bleed hole is no...

Page 5: ...damage seal and will void warranty 3 Pick up pump by the rope provided not by the cord and lower into the pool Place pump in lowest point of pool To avoid severe injury or fatal electrical shock do n...

Page 6: ...utlet B Check GFCI in outlet for tripping GFCI protects against dangerous current leaks to ground If GFCI has tripped and will not reset DO NOT USE PUMP until problem is repaired C If motor runs for a...

Page 7: ...55SS 6 Float Rod 1 PS28 17 7 Float 1 PS28 18 8 Rubber Rod Stop 1 RP0005248 9 Rubber Gasket 1 RP0001616 10A Retainer Ring 2 PS43 10 10B Check Valve 1 PS20 12 11 Locknut 8 32 1 U36 129DN 12 Machine Scre...

Page 8: ...S958 Rev B 04 14 10 S958...

Reviews: