background image

Troubleshooting

14

* (Note: 

Stop pump;

then check prime
before looking for
other causes.
Unscrew priming
plug and see if water
is in priming hole).

SYMPTOM

POSSIBLE CAUSE(S)

CORRECTIVE ACTION

Motor will not run

Disconnect switch is off

Be sure switch is on.

Fuse is blown or circuit breaker tripped

Replace fuse or reset circuit breaker.

Starting switch is defective

DISCONNECT POWER; Replace starting switch.

Wires at motor are loose, 

Refer to instructions on wiring (Page 8). DISCONNECT POWER; check and

disconnected, or wired incorrectly 

tighten all wiring. 

Capacitor voltage may be hazardous. To discharge 

capacitor, hold insulated handle screwdriver BY THE HANDLE and 
short capacitor terminals together. Do not touch metal screwdriver 
blade or capacitor terminals. If in doubt, consult a qualified electrician.

Pressure switch contacts are dirty

DISCONNECT POWER and file contacts with emery board or nail file.

Motor runs hot and 

Motor is wired incorrectly

Refer to instructions on wiring.

overload kicks off

Voltage is too low

Check with power company. Install heavier wiring if wire size is too small  
(See Electrical / Wiring Chart).

Pump cycles too frequently

See section below on too frequent cycling.

Motor runs but no 

Pump in new installation did 

In new installation:

water is delivered*

not pick up prime through: 

1. Improper priming 

1. Re-prime according to instructions.

2. Air leaks

2. Check all connections on suction line, AVC, and ejector with

soapy water or shaving cream.

3. Leaking foot valve or check valve

3. Replace foot valve or check valve.

Pump has lost prime through:

In installation already in use:

1. Air leaks

1. Check all connections on suction line and shaft seal.

2. Water level below suction pipe inlet

2. Lower suction line into water and re-prime. If receding water level 

in well exceeds 25’ (7.6M), a deep well pump is needed.

Foot valve or strainer is plugged

Clean foot valve or strainer.

Ejector or impeller is plugged

Clean ejector or impeller.

Check valve or foot valve is stuck shut 

Replace check valve or foot valve.

Pipes are frozen

Thaw pipes. Bury pipes below frost line. Heat pit or pump house.

Foot valve and/or strainer are 

Raise foot valve and/or strainer above bottom of water source.

buried in sand or mud

Clean foot valve and strainer.

Pump does not 

Water level in well is lower than 

A deep well jet will be needed if your well is more than 25’ (7.6M)

deliver water to full 

estimated

depth to water.

capacity 

Steel piping (if used) is corroded or 

Replace with plastic pipe where possible, otherwise with new steel pipe.

(Also check point

limed, causing excess friction

3 immediately above)

Offset piping is too small in size

Use larger offset piping.

Pump delivers water but

Pressure switch is out of adjustment or

DISCONNECT POWER; adjust or replace pressure switch.

does not shut off or

contacts are welded together

pump cycles too

Faucets have been left open

Close faucets.

frequently

Venturi, nozzle or impeller is clogged

Clean venturi, nozzle or impeller.

Water level in well is lower 

Check possibility of using a deep well jet pump

than estimated
Standard pressure tank is waterlogged

Drain tank to air volume control port. Check AVC for defects. Check 

and has no air cushion

all connections for air leaks.

Pipes leak

Check connections.

Foot valves leak

Replace foot valve.

Pressure switch is out of adjustment

Adjust or replace pressure switch

Air charge too low in pre-charged tank

DISCONNECT POWER and open faucets until all pressure is relieved.
Using tire pressure gauge, check air pressure in tank at valve stem 
located on the tank. If less than pressure switch cut-in setting (30-50 
PSI), pump air into tank from outside source until air pressure is 2 PSI 
less than cut-in setting of switch. Check air valve for leaks (use soapy
solution) and replace core if necessary.

Air spurts from faucets

Pump is picking up prime

When pump has picked up prime, it should pump solid water with no air.

Leak in suction side of pump

Suction pipe is sucking air. Check joints for leaks with soapy water.

Well is gaseous

Consult factory about installing a sleeve in the well

Intermittent over-pumping of well.

Lower foot valve if possible, otherwise restrict pump discharge

(Water drawn down below foot valve.)

Summary of Contents for MSC-6

Page 1: ...umps 20 100 80 60 40 2001 Sta Rite Industries Inc PRINTED IN U S A S757 1 Rev 10 31 01 293 Wright Street Delavan WI 53115 MS Series Installation Operation Parts For further operating installation or m...

Page 2: ...GENERAL SAFETY Do not touch an operating motor Modern motors are designed to operate at high temperatures To avoid burns when servicing pump allow it to cool for 20 minutes after shut down before hand...

Page 3: ...duty is to repair or replace defective products at Sta Rite s choice Buyer agrees to pay all labor and shipping charges associated with this warranty and to request warranty service through the instal...

Page 4: ...equirements usually pipe must by 12 below frost line and pump must be insulated Step 4 Be sure all pipes and foot valve are clean and in good shape Step 5 No air pockets in suction pipe Step 6 No leak...

Page 5: ...at least 10 to 20 feet below the lowest water level with pump running if possi ble but always at least five feet from the bottom of the well Step 8 Tighten all hose clamps securely on plastic pipe Use...

Page 6: ...e well see Figure 8 Step 4 To properly seat the cup seals after the ejector is correctly posi tioned move the assembly up and down slightly Water pressure in the casing will then soak the cup seals se...

Page 7: ...pump and to AVC on tank See installation instructions provid ed with tank and AVC for details PRECHARGED TANK CONNECTION When a precharged tank is used no AVC is necessary See Figure 10 for typical p...

Page 8: ...oltage motor Connect power supply as shown for your type of switch and your supply voltage Pull plug straight out from terminal board 1 1 2 2 Plug in again with arrow on plug pointing to 115 Volts A L...

Page 9: ...ure 12 The ground wire must be a solid copper wire at least as large as the power sup ply wires Step 2 There must be a solid metal connection between the pressure switch and the motor for motor ground...

Page 10: ...more as ejector and pump prime IF NO PRESSURE OR NO WATER REPEAT Step No 1 above two or three times to remove entrapped air from the suction pipes Step 3 If after priming pump several times no water...

Page 11: ...In this case operate pump with regulator valve open HOW TO HANDLE A GASEOUS WELL In some areas well water contains gases which must be allowed to escape before the water is used To deliver gas free w...

Page 12: ...a small screwdriver or thin bladed chisel in between the intermediate volute and the pump adapter in two or three places around the pump to separate the castings Figure 20 Do not mar the sealing surfa...

Page 13: ...e up with the water passages in the volutes Step 9 Install the intermediate volute aligning it with the mark made before disassembly Use the long cap screws to check this align ment It cannot be stres...

Page 14: ...k valve or foot valve Pipes are frozen Thaw pipes Bury pipes below frost line Heat pit or pump house Foot valve and or strainer are Raise foot valve and or strainer above bottom of water source buried...