STA-RITE JHSC-61USF Owner'S Manual Download Page 5

5

The system must be built so that it cannot operate with the pump drawing
water from only 

one main drain (that is, there must be at least two main drains

connected to the pump whenever it is running). However, if two main drains
run into a single suction line, the single suction line may be equipped with a
valve which will shutoff 

both main drains from the pump.

More than one pump can be connected to a single suction line as long as the
requirements above are met.

Water Velocity

The maximum water velocity through any suction outlet must be 1.5 feet per
second unless the outlet complies with the latest ASME/SNSI Specification for
Suction Fittings For Use in Swimming Pools, Spas, Hot Tubs, and Whirlpool
Bathtub Applications. In any case, do not exceed the suction fittings maxi-
mum designed flow rate.
If 100% of the pump’s flow comes from the main drain system, the maximum
water velocity in the pump suction hydraulic system must be six feet per sec-
ond or less even if one main drain (suction fitting) is completely blocked. The
flow through the remaining main drain(s) must comply with the latest
ASME/ANSI Specification for 

Suction Fittings For Use in Swimming Pools,

Spas, Hot Tubs, and Whirlpool Bathtub Applications.

ELECTRICAL

Ground motor before connecting to electrical power supply. Failure to

ground motor can cause severe or fatal electrical shock hazard.

Do not ground to a gas supply line.

To avoid dangerous or fatal electrical shock, turn OFF power to motor

before working on electrical connections.

Ground Fault Circuit Interrupter (GFCI) tripping indicates an electrical

problem. If GFCI trips and will not reset, have a qualified electrician
inspect and repair electrical system.

Exactly match supply voltage to nameplate voltage. Incorrect voltage

can cause fire or seriously damage motor and voids warranty.
If in doubt consult a licensed electrician.

Voltage

Voltage at motor must be not more than 10% above or below motor name-
plate rated voltage or motor may overheat, causing overload tripping and re-
duced component life. If voltage is less than 90% or more than 110% of rated
voltage when motor is running at full load, consult power company.

Hazardous voltage.
Can shock, burn,
or cause death.

Ground pump before
connecting to
power supply.

Summary of Contents for JHSC-61USF

Page 1: ...rica 800 752 0183 FAX 800 582 2217 International 262 728 5551 FAX 262 728 4461 TELEX ITT 4970245 www sta ritepool com Union City TN Delavan WI Mississauga Ont Murrieta CA 2001 Sta Rite Industries Inc Printed in U S A S533 Rev 9 19 01 This manual should be furnished to the end user of this pump its use will reduce service calls chance of injury and will lengthen pump life 3551 1099 ASB ...

Page 2: ...er system 2 Use equipment only in a pool or spa installation 3 Install pump with at least 2 hydraulically balanced main drains equipped with correctly installed screw fastened anti entrapment certified covers See Page 4 4 Trapped air in system can cause explosion BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks Check al...

Page 3: ... threads with one to two layers of Teflon tape Cover entire threaded portion of pipe Do not overtighten If leaks occur remove pipe clean off old tape rewrap with one to two addi tional layers of tape and remake the connection NOTICE Support all piping connected with pump Piping Use at least 1 1 4 IPS PVC pipe for pump suction Increase size if a long run is needed To avoid strains on the pump suppo...

Page 4: ...fastened covers in place Testing and Certification Suction outlet covers must have been tested by a nationally recognized testing laboratory and found to comply with the lastest ASME ANSI Specification for Suction Fittings For Use in Swimming Pools Spas Hot Tubs and Whirlpool Bathtub Applications Outlets Per Pump see Figure 1 Provide at least two hydraulically balanced main drains with covers for ...

Page 5: ...ked The flow through the remaining main drain s must comply with the latest ASME ANSI Specification for Suction Fittings For Use in Swimming Pools Spas Hot Tubs and Whirlpool Bathtub Applications ELECTRICAL Ground motor before connecting to electrical power supply Failure to ground motor can cause severe or fatal electrical shock hazard Do not ground to a gas supply line To avoid dangerous or fata...

Page 6: ...ectrical equipment metal piping or conduit within 5 feet 1 5 m of the inside walls of swimming pool spa or hot tub Wiring Pump must be permanently connected to circuit See Table I for correct wire and circuit breaker sizes for the pump alone If other lights or appliances are also on the same circuit be sure to add their amp loads to pump amp load before figuring wire and circuit breaker sizes If u...

Page 7: ...Page 10 Draining Pump 1 Pump down water level below all inlets to the pool To avoid dangerous or fatal electrical shock hazard turn OFF power to motor before draining pump 2 To prevent pump from freezing drain the pump body through the drain plug Key No 12 Page 11 Clean pump thoroughly 3 Cap inlet piping after draining to keep water out of the pipes 4 Be sure motor is kept dry and covered Storage ...

Page 8: ...iceman repair wiring as needed 4 Inspect and tighten all watertight connections 5 Open all valves in suction and return piping 6 Remove any winterizing plugs in piping system 7 Drain all antifreeze from system 8 Close all drain valves and replace all drain plugs in piping system 9 Prime pump according to instructions on Page 7 PUMP SERVICE Pump should only be serviced by qualified personnel Be sur...

Page 9: ...ed surface of floating seat with clean cloth 2 Turn seal plate over so seal cavity is up clean cavity thoroughly 3 Lubricate outside rubber surface of ceramic seat with soapy water and press firmly into seal cavity with finger pressure If seat will not locate prop erly in this manner place cardboard washer over polished face of seat and press into seal cavity using a 3 4 socket or 3 4 piece of sta...

Page 10: ...Clogged pipe impeller worn impeller 5 Make sure impeller is not clogged follow instructions under Removal of Old Seal Page 9 check impeller for clogging follow instructions under Installation of Rotating Part of Seal Unit Page 9 for reassembly 6 Impeller may be worn If so order replacement parts from Repair Parts List Page 11 7 Pump may be trying to push too high a column of water If so a higher h...

Page 11: ...3 8 16x1 1 2 Hex Hd 2 U30 76ZP 15 Motor Pad 1 C35 5 Voltage Sticker 115 230 Volts U27 153 Nameplate U33 155 Not illustrated 1 10 11 2 3 4 5 12 12 6 9 7 8 13 15 14 3551 1099 11 REPAIR PARTS LIST 1 2 through 1 1 2 HP Models JHSC 61USF JHSD 62USF JHSE 63USF JHSF 51USF Motor No Impeller Model No HP Key No 1 Key No 9 115 230 Volt JHSC 61USF 1 2 A100CLL C105 92PNX JHSD 62USF 3 4 A100DLL C105 92PMX JHSE ...

Page 12: ...r pur chaser Purchaser only Sta Rite shall have the option to re pair or replace the defective product at its sole discre tion Purchasers must pay all labor and shipping charges nec essary to replace the product covered by this warranty Requests for warranty service must be made through the in stalling dealer This warranty shall not apply to any product that has been subject to negligence misappli...

Reviews: