ELECTRICAL

Ground motor before connecting to electrical power supply! Failure to

ground pump motor can cause serious or fatal electrical shock hazard!

Do not ground to a gas supply line!

To avoid dangerous or fatal electrical shock, turn OFF power to motor

before working on electrical connections.

GFCI tripping indicates an electrical problem. If GFCI trips and will not

reset, have a qualified electrician inspect and repair electrical system.

Exactly match supply voltage to nameplate voltage (115 Volt or 230

Volt single phase only)! Incorrect voltage can cause fire or seriously

damage motor and voids warranty!

Grounding:

Install, ground, and wire motor according to local or National Electrical Code
requirements.
Permanently ground motor; use size and type wire required by code.
Ground connection must be made to green grounding terminal under motor
canopy or access plate (see Figure 1B).
Connect motor ground terminal to electrical service ground.
Install and bond pump according to local codes and ordinances; use bonding
lug on motor (see Figure 1A). Use solid copper conductor No. 8 AWG
(8.4mm

2

) or larger.

Wiring:

Pump must be permanently connected to circuit. Table I, Page 6, gives correct
wire and circuit breaker sizes for the pump alone. If other lights or appliances
are also on the same circuit, be sure to add their amp loads to pump amp load
before figuring wire and circuit breaker sizes. (If unsure how to do this or if
this is confusing, consult a licensed electrician.) Use the load circuit breaker
as the master on-off switch.
Install a Ground Fault Circuit Interrupter (GFCI) in circuit; it will sense a short-
circuit to ground and disconnect power before it becomes dangerous to pool
users. For size of GFCI required and test procedures for GFCI, see manufac-
turer’s instruction.
In case of power outage, check GFCI for tripping (which will prevent normal
pump operation). Reset if necessary. 

NOTICE: 

If you do not use conduit when wiring motor, 

be sure

to seal wire

opening on end of motor to prevent dirt, bugs, etc., from entering.

Hazardous voltage.
Can shock, burn,
or cause death.

Ground pump before
connecting to
power supply.

BONDING

LUG

MOTOR NAMEPLATE

GREEN

GROUND

SCREW

MOTOR

CANOPY

THROUGH

BOLTS

499 0993

Figure 1A: Typical ground screw and
bonding lug locations.

White 

230
Volt
Lines

A

B

L2

L1

Blue

SINGLE

VOLTAGE

MOTORS

DUAL

VOLTAGE

MOTORS

A

B

L2

L1

White
w/Black 
Tracer

Black

115
Volt
Lines

A

B

L2

L1

White
w/Black 
Tracer

Black

230
Volt
Lines

Motor Terminal Board Connections

Figure 1B. Motor terminal block
connections.

Summary of Contents for DURA-JET JSACL

Page 1: ...p 293 Wright Street Delavan WI 53115 North America 800 752 0183 FAX 800 582 2217 International 262 728 5551 FAX 262 728 4461 TELEX ITT 4970245 www sta ritepool com Union City TN Delavan WI Mississauga...

Page 2: ...AL CAREFULLY The Sta Rite JS Series Tub Pump Is designed to circulate hot water in spas and hot tubs Is an excellent performer durable reliable Table of Contents Safety Instructions 3 Installation 4 E...

Page 3: ...BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks Check all clamps bolts lids and system accessories before testing Relea...

Page 4: ...r compartment Piping Use flexible or rigid PVC pipe for connections to pump Suction discharge piping gate valves will allow removal for servicing Use at least 1 1 2 IPS pipe Fittings restrict flow for...

Page 5: ...le I Page 6 gives correct wire and circuit breaker sizes for the pump alone If other lights or appliances are also on the same circuit be sure to add their amp loads to pump amp load before figuring w...

Page 6: ...HP Volts Amps Amp Rating 0 30 31 60 61 90 Deg C Single Speed Pumps JSACL A 1 2 115 7 0 15 14 2 0 12 3 0 10 5 5 75 JSADL 2A 3 4 115 9 0 15 14 2 0 14 2 0 10 5 5 75 JSAEL 2A 1 115 12 0 15 14 2 0 10 5 5...

Page 7: ...ng when system is not in use Failure to do so can allow air to enter system causing pump to lose its prime Keep water temperature at 104 F 40 C or below Age or health conditions may require a lower te...

Page 8: ...e drive ring seats and seals 6 Carefully remove four motor throughbolts from seal plate Figure 3 remove seal plate and use a screwdriver to tap ceramic seat out from the rear Figure 4 Do not damage se...

Page 9: ...f possible store chemicals in another room Allowing pump to freeze will damage pump and void warranty Drain all water from pump and piping when expecting freezing temperatures or when storing pump for...

Page 10: ...the low point of the spa piping to help drain spa system 6 Before restarting replace all plugs and make sure all pipe connections are tightly sealed Startup for Winterized Equipment 1 Remove any tempo...

Page 11: ...use poor flow and poor jet action 2 Consult dealer installer or service representative C EXCESSIVE AIR IN SYSTEM PUMP LOSES PRIME 1 Make sure water level in spa is at least 2 51 mm above top of jets w...

Page 12: ...1 JSAEFL A 11 2 AE910FLL 17301 0101 230 Volt Single Speed JSADL 230A 3 4 AS923DL C105 228PB JSAEL 230A 1 AS923EL C105 228P 230 Volt Two Speed JSAYDL 230A 3 4 AS923DL Y C105 228PB JSAYEL 230A 1 AS923EL...

Page 13: ...13...

Page 14: ...14...

Page 15: ...15...

Page 16: ...pur chaser Purchaser only Sta Rite shall have the option to re pair or replace the defective product at its sole discre tion Purchasers must pay all labor and shipping charges nec essary to replace t...

Reviews: