LIMITED WARRANTY
Sta-Rite Industries, Inc., warrants to the original consumer of the products listed below, that they will be free from defects in material and work-
manship for the Warranty Period from the date of original installation or manufacture as noted.
Product
Warranty Period
Water Systems Products – jet pumps,
whichever occurs first:
small centrifugal pumps, submersible pumps
1 year from date of original installation, or
and related accessories
2 years from date of manufacture
Hydro-Flow Filters
1 year from date of purchase
Signature 2000
®
Fibrewound Tanks
5 years from date of original installation
Pro-Source
TM
Steel Pressure Tanks
5 years from date of original installation
Pro-Source
TM
Epoxy-Lined Tanks
3 years from date of original installation
Sump/Sewage/Effluent Products
1 year from date of original installation, or
2 years from date of manufacture
Our warranty will not apply to any product that has been subject to negligence, misapplication, improper installation or maintenance. In the event
a three phase submersible motor is operated with single phase power through a phase converter, or if three-leg ambient compensated, extra-
quick trip overload relays of recommended size are not used, our warranty is void.
Buyer’s only remedy and Sta-Rite Industries, Inc.’s only duty is to repair or replace defective products (at Sta-Rite Industries, Inc.’s choice). Buyer
agrees to pay all labor and shipping charges associated with this warranty and to request warranty service through the installing dealer as soon
as a problem is discovered. If warranty service is requested more than 30 days after the Warranty Period has ended, it will not be honored.
STA-RITE INDUSTRIES, INC. SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES
WHATSOEVER.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES. IMPLIED WARRANTIES,
INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE,
SHALL NOT EXTEND BEYOND THE WARRANTY PERIOD PROVIDED HEREIN.
Certain states do not permit the exclusion or limitation of incidental or consequential damages or the placing of limitations on the duration of an
implied warranty, therefore, the limitations or exclusions herein may not apply. This warranty sets forth specific legal rights and obligations, how-
ever, additional rights may exist, which may vary from state to state.
Supersedes all previous publications.
Sta-Rite Industries, Inc. 293 Wright St., Delavan, WI 53115
TROUBLES-REMEDIES
A. Pump fails to operate:
1. Check to be sure that power cord is securely plugged into outlet or securely wired
into controller or switch box. Disconnect power to outlet before handling pump
or motor.
2. Check to be sure you have electrical power.
3. Check that liquid fluid level is high enough to activate switch or controller.
4. Check to be sure that 3/16” (5 mm) vent hole in discharge pipe is not plugged.
5. Check for blockage in pump inlet, impeller, check valve or discharge pipe.
6. Thermal overload may have tripped. Test start pump; if it starts and then stops
immediately, disconnect from power source for 30 minutes to allow motor to cool,
then reconnect to power source. Check for cause of overheating/overloading.
B. Pump fails to empty sump:
1. Be sure all valves in discharge piping are fully open.
2. Clean out discharge pipe and check valve.
3. Check for blockage in pump inlet or impeller.
4. Pump not sized properly. A higher capacity pump may be required.
C. Pump will not shut off:
1. Check switch or controller automatic floats for proper operation and location.
See installation instructions for switch/controller.
2. If pump is completely inoperative or continues to malfunction, consult your
local serviceman.
Sudden Starts. If power is on to pump
when thermal overload resets, pump may start with-
out warning. If you are working on pump, you
may get an electrical shock or impeller may catch
fingers or tools.
Disconnect power before servicing
pump.