background image

8

7. Remove four screws holding seal plate to motor.

8. Place seal plate face down on flat surface and tap out

ceramic seat (Fig. 5).

9. Remove slinger from motor shaft and inspect for dam-

age or abrasion.

10. Clean seal cavity in seal plate and clean motor shaft.

Pump Reassembly/Installing New Seal

1. Ceramic seat must be clean and free of dirt, grease,

dust, etc. Wet outer edge with small amount of liquid
detergent; press ceramic seat into seal plate cavity
firmly and squarely with finger pressure (Fig. 6).

2. If ceramic seat will not locate properly, remove it,

place 

ffaaccee  u

up

p  

on bench and reclean cavity. Ceramic

seat should now locate.

3. If seat still will not locate properly, place a cardboard

washer over the polished face and use a piece of 3/4"
(19mm) standard pipe for pressing purposes. 

N

NO

OT

TIIC

CEE::  B

Bee  ssu

urree  

not to scratch or mar polished sur-

face or seal will leak.

4. Replace slinger on end of motor shaft so that impeller

sleeve will push it into position. If slinger shows signs
of wear or damage, replace it.

5. Remount seal plate on motor. Tighten bolts to 60-80

inch-lbs. (69-92 kg/cm) torque.

6. Apply a 

ssm

maallll  

amount of liquid detergent to inside di-

ameter of rotating half of seal.

7. Slide rotating seal member, polished carbon face out,

over impeller sleeve until rubber drive ring hits back
of impeller.

N

NO

OT

TIIC

CEE::  B

Bee  ssu

urree  

not to nick or scratch polished seal

face; seal will leak if face is damaged.

8. Screw impeller onto shaft (clockwise); this will auto-

matically locate seal in seal plate.

N

NO

OT

TIIC

CEE::

On 2 HP, 2-1/2 HP and 3-Phase models;

install impeller gasket and lock screw (left-hand
thread - turn counterclockwise). Torque lock screw to
50-55 inch-lbs. (57.6-63 kg/cm).

9. Mount diffuser on seal plate; tighten screws to 10-14

inch-lbs. (11.2-16.1 kg/cm) torque.

10. Assemble motor and seal plate to pump body with

nuts, flat washers and lock washers. Torque nuts to
120-130 in-lbs. (138-150 kg/cm).

11. Prime pump according to instructions on Page 6.

Figure 5

Figure 6

Summary of Contents for 5TPRAYF-156

Page 1: ...HP TPEAG 167LS TPEAYG 175L TPEAYG 175LS 2 1 2 HP TPEAAG 168L TPEAAYG 168L 2 1 2 HP TPEAAG 168LS TPEAAYG 168LS Sta Rite Pool Spa Group 293 Wright Street Delavan WI 53115 International 262 728 5551 FAX...

Page 2: ...a trained pool professional perform all pressure tests 1 Do not connect system to a high pressure or city water system 2 Use equipment only in a pool or spa installation 3 Trapped air in system can ca...

Page 3: ...gs Wrap male pipe threads with one to two layers of Teflon tape Cover entire threaded portion of pipe D Do o n no ot t overtighten or tighten past thread stop in pump port If leaks occur remove pipe c...

Page 4: ...l connections Ground Fault Circuit Interrupter GFCI trip ping indicates an electrical problem If GFCI trips and will not reset have a qualified electrician inspect and repair electrical system 6 3 4 1...

Page 5: ...ult Circuit Interrupter GFCI as master on off switch it will sense a short circuit to ground and dis connect power before it becomes dangerous to pool users Test according to maker s instructions In c...

Page 6: ...M Motor Branch Fuse Max Load Voltage 0 100 101 200 201 300 HP Rating Amps Amps Hz Phase 0 30 30 60 60 90 T TP PE EA A M Mo od de el ls s 1 20 15 12 6 6 3 115 230 60 1 12 3 14 2 10 5 14 2 8 7 14 2 1 1...

Page 7: ...to prime pump Pg 6 before starting 1 1 S ST TO OP P P PU UM MP P b be ef fo or re e p pr ro o c ce ee ed di in ng g 2 2 C CL LO OS SE E G GA AT TE E V VA AL LV VE ES S i in n s su uc ct ti io on n a a...

Page 8: ...r on end of motor shaft so that impeller sleeve will push it into position If slinger shows signs of wear or damage replace it 5 Remount seal plate on motor Tighten bolts to 60 80 inch lbs 69 92 kg cm...

Page 9: ...talling New Seal Page 8 for reassembly 2 Impeller and diffuser may be worn If so order re placement parts from Repair Parts List Page 10 E El le ec ct tr ri ic ca al l 1 Pump may be running too slowly...

Page 10: ...8 Ext Tooth 7 U43 21SS 19 Flat Washer 3 8 6 U43 62SS 20 Lock Washer 3 8 6 U43 12SS 21 Nut 3 8 16 Hex 6 071403 22 Cap Screws 3 8 16x1 Hex 4 U30 74SS Nameplate 1 U33 174 Tag Warning Caution Instruction...

Page 11: ...lbs ac cessories and fittings manufactured by Sta Rite are warranted to be free of defects in material and or workmanship for one 1 year from the original date of installation The foregoing warranties...

Reviews: