background image

6

To Wire a Two-Speed Motor

Wire the pump as shown in the diagram. 

OPERATION

N

NO

OT

TIIC

CEE::  

NEVER run pump dry. Running pump dry may

damage seals, causing leakage and flooding. Fill pump
with water before starting motor.

D

Do

o  n

no

ott  b

bllo

occkk  p

pu

um

mp

p  ssu

ucc--

ttiio

on

n..  T

To

o  d

do

o  sso

o  w

wiitth

h

b

bo

od

dyy  m

maayy  ccaau

ussee  sseevveerree  o

orr

ffaattaall  iin

njju

urryy..  SSm

maallll  cch

hiilld

drreen

n

u

ussiin

ngg  p

po

oo

oll  m

mu

usstt  A

ALLW

WA

AY

YSS

h

haavvee  ccllo

ossee  aad

du

ulltt  ssu

up

peerrvviissiio

on

n..

Priming Pump

Release all air from filter and
piping system: see filter
owner’s manual.
In a flooded suction system
(water source higher than
pump), pump will prime itself
when suction and discharge
valves are opened.

Storage/Winterizing:

N

NO

OT

TIIC

CEE::  

Allowing pump to freeze will damage pump

and void warranty!

N

NO

OT

TIIC

CEE::  D

Do

o  n

no

ott  

use anti-freeze solutions (except propy-

lene glycol) in your pool/spa system. Propylene glycol is
non-toxic and will not damage plastic system compo-
nents; other anti-freezes are highly toxic and may dam-
age plastic components in the system.

TABLE I - RECOMMENDED FUSING AND WIRING DATA

NOTICE: Series TPEA and TPRA pumps use 60 Cycle current only.

Serv. to Motor - Dist. in Ft. (M)

Motor

Branch Fuse

Max Load

Voltage/

0-100'

101-200'

201-300'

HP

Rating Amps*

Amps

Hz/Phase

(0-30)

(30-60)

(60-90)

T

TP

PEEA

A M

Mo

od

deellss::

1

20/15

12.6/6.3

115/230/60/1 12(3)/14(2) 10(5/14(2)

8(7)/14(2)

1-1/2

25/15

16.0/8.0

115/230/60/1 12(3)/14(2) 8(7)/14(2) 6(13)/14(2)

2

15

10.4

230/60/1

14(2)

14(2)

14(2)

2-1/2

15

11.2

230/60/1

14(2)

12(3)

12(3)

T

TP

PEEA

AY

Y  M

Mo

od

deellss  ((2

2--ssp

peeeed

d))::

2

15

10.1/3.7

230/60/1

14(2)

14(2)

14(2)

2-1/2

15

11.9/3.5

230/60/1

14(2)

12(3)

12(3)

T

TP

PR

RA

A M

Mo

od

deellss::

1

15

3.6/1.8

208-230/460/60/3

14(2)

14(2)

14(2)

1-1/2

25/15

19.2/9.6

115/230/60/1 10(5)/14(2) 8(7)/14(2) 6(13)/12(3)

2

15

12.0

230/60/1

14(2)

14(2)

12(3)

T

TP

PR

RA

A M

Mo

od

deellss  ((2

2--SSp

peeeed

d))::

1-1/2

15

9.2/2.5

230/60/1

14(2)

14(2)

12(3)

5

5T

TP

PR

RA

AY

Y  M

Mo

od

deell  ((2

2--ssp

peeeed

d))::

1-1/2

15

8.3/3.0

230/50/1

14(2)

14(2)

12(3)

* Time delay fuses are recommended instead of standard fuses in any motor circuit.

A

AW

WG

G

W

Wiirree

SSiizzee

((m

mm

m

2

2

))

}

Figure 4C - 2-Speed Motor Wiring Diagram

L

2

=

C

O

M

 

 

L

1

=

H

I

 

A

=

L

O

W

A

L2

L1

Power Supply for

Optional Timer. 

Low Speed

High Speed

Circuit

Protector

Remote

SPDT

Switch

Ground (Green)

Common

If using timer, Connect 
Timer Motor  to Low Speed Only

Minimum switch and timer amp rating must equal Branch Fuse
Rating given in "Recommended Fusing and Wiring Data" table.

230
Volt

Lines

Back of
motor
with 
Terminal
Board

4558 0304

Hazardous suction.
Can trap hair or body
parts, causing severe
injury or death.

Do not block suction. 
Do not operate system
with broken or missing
drain covers.

Summary of Contents for 5TPRAYF-156

Page 1: ...HP TPEAG 167LS TPEAYG 175L TPEAYG 175LS 2 1 2 HP TPEAAG 168L TPEAAYG 168L 2 1 2 HP TPEAAG 168LS TPEAAYG 168LS Sta Rite Pool Spa Group 293 Wright Street Delavan WI 53115 International 262 728 5551 FAX...

Page 2: ...a trained pool professional perform all pressure tests 1 Do not connect system to a high pressure or city water system 2 Use equipment only in a pool or spa installation 3 Trapped air in system can ca...

Page 3: ...gs Wrap male pipe threads with one to two layers of Teflon tape Cover entire threaded portion of pipe D Do o n no ot t overtighten or tighten past thread stop in pump port If leaks occur remove pipe c...

Page 4: ...l connections Ground Fault Circuit Interrupter GFCI trip ping indicates an electrical problem If GFCI trips and will not reset have a qualified electrician inspect and repair electrical system 6 3 4 1...

Page 5: ...ult Circuit Interrupter GFCI as master on off switch it will sense a short circuit to ground and dis connect power before it becomes dangerous to pool users Test according to maker s instructions In c...

Page 6: ...M Motor Branch Fuse Max Load Voltage 0 100 101 200 201 300 HP Rating Amps Amps Hz Phase 0 30 30 60 60 90 T TP PE EA A M Mo od de el ls s 1 20 15 12 6 6 3 115 230 60 1 12 3 14 2 10 5 14 2 8 7 14 2 1 1...

Page 7: ...to prime pump Pg 6 before starting 1 1 S ST TO OP P P PU UM MP P b be ef fo or re e p pr ro o c ce ee ed di in ng g 2 2 C CL LO OS SE E G GA AT TE E V VA AL LV VE ES S i in n s su uc ct ti io on n a a...

Page 8: ...r on end of motor shaft so that impeller sleeve will push it into position If slinger shows signs of wear or damage replace it 5 Remount seal plate on motor Tighten bolts to 60 80 inch lbs 69 92 kg cm...

Page 9: ...talling New Seal Page 8 for reassembly 2 Impeller and diffuser may be worn If so order re placement parts from Repair Parts List Page 10 E El le ec ct tr ri ic ca al l 1 Pump may be running too slowly...

Page 10: ...8 Ext Tooth 7 U43 21SS 19 Flat Washer 3 8 6 U43 62SS 20 Lock Washer 3 8 6 U43 12SS 21 Nut 3 8 16 Hex 6 071403 22 Cap Screws 3 8 16x1 Hex 4 U30 74SS Nameplate 1 U33 174 Tag Warning Caution Instruction...

Page 11: ...lbs ac cessories and fittings manufactured by Sta Rite are warranted to be free of defects in material and or workmanship for one 1 year from the original date of installation The foregoing warranties...