If the fault is set as “Not latched” the system will try to restart after the time defined by the “Non latched faults
timer” parameter.
If the fault is set as “Latched” the switching activity will remain off and the V
CC
will remain between 15 V and 17 V
using the HV start-up generator (as long as there is the mains connected).
3.2.15
LLC OLP behavior
Size: 1 bit
Sets the behavior of the LLC overload protection (OLP).
Available values are:
•
Not latched
•
Latched
If the fault is set as “Not latched” the system will try to restart after the time defined by the “Non latched faults
timer”.
If the fault is set as “Latched” the switching activity will remain off and the V
CC
will remain between 15 V and 17 V
using the HV start-up generator (as long as there is the mains connected).
3.2.16
LLC OVP behavior
Size: 1 bit
Sets the behavior of the LLC OVP.
Available values are:
•
Not latched
•
Latched
If the fault is set as “Not latched” the system will try to restart after the time defined by the “Non latched faults
timer” parameter.
If the fault is set as “Latched” the switching activity will remain off and the V
CC
will remain between 15 V and 17 V
using the HV start-up generator (as long as there is the mains connected).
3.3
PFC parameters
3.3.1
PFC Ki
Size:3 bits
Sets the integral constant of the PFC compensation filter.
Available values are:
•
4
•
6
•
8
•
12
•
16
•
24
•
32
•
48
3.3.2
PFC Kp
Size:3 bits
Sets the proportional constant of the PFC compensation filter.
Available values are:
•
8
•
12
•
16
•
24
•
32
UM3002
PFC parameters
UM3002
-
Rev 1
page 9/42