Wiring setup of the output sensing and relay board
●
Connect J6 (multi-output power supply board) to VDC (relay board)
●
Connect 24 V (multi-output power supply board) to J11 (relay board)
●
Connect J1 (control board) to J12 (relay board)
Open loop operation
The control firmware can operate either in open loop or closed loop mode. The open loop
mode of operation has been included to allow debugging and component evaluation when
the system is not connected to the grid and therefore delivering power to a suitable external
load. The open loop function and hardware configuration allows also to independently test
both the DC-DC converter and the DC-AC converter. In this case, connector J9 shown in
, can be used to either connect an electrical load when testing the DC-DC converter
or to connect a DC power supply when testing the DC-AC inverter.
Figure 9.
Input and output power connectors