INSTALLATION AND SYSTEM DESCRIPTION

FOR  SSZ CONTROL UNIT 

TYPE SSZ-RZ3

Summary of Contents for SSZ-RZ3

Page 1: ...www ssz gmbh de info ssz gmbh de Th ringerstrasse 17 46286 Dorsten 1 MADE IN GERMANY INSTALLATION AND SYSTEM DESCRIPTION FOR SSZ CONTROL UNIT TYPE SSZ RZ3...

Page 2: ...mpers Response time 20 ms Reset function automatic manual Control unit identification is provided with the number printed on a hologram on the housing For proper device identification the Installer sh...

Page 3: ...NTENANCE AND CONTROL OF PROPER FUNCTIONALITY 12 STORAGE AND TRANSPORT 14 UTILISATION 14 NOTES 14 These instructions form is an essential part of the product These instructions contains basic informati...

Page 4: ...ts a control unit The system shall be connected to a machine by properly trained technical personnel only In no event shall the SSZ GmbH Company be liable for any damages arising from or being a conse...

Page 5: ...trol unit all the electric machines devices to be connected must be switched off from voltage supply OPERATION FAILURE DUE TO OVERHEATING A pressure sensitive product SSZ safety mat SSZ safety edge or...

Page 6: ...y the SSZ control unit is an appropriate device to control the SSZ pressure sensitive product Any replacements of devices of a control unit or of a pressure sensitive product by a solution of other ma...

Page 7: ...esponse time 20ms Performance Level acc to EN ISO 13849 1 PL d Pl e The service life 287 years MTTFd in connection with SSZ presure equip ment 74 1 DC diagnostic coverage 90 CCF common cause failure 7...

Page 8: ...g the safety evaluation rules and this category shall be regarded valid because whole system has to be considered Prior to the system connection the installer is obliged to read the operating manual o...

Page 9: ...rminals 3 5 is broken the K1 relay shall be inactivated Simulation of the broken cable If the connection of terminals 4 6 is broken the K2 relay shall be inactivated Simulation of the broken cable In...

Page 10: ...all be integrated with the machine emergency switch circuit Unless the pressure sensitive device is activated the relay contacts i e also the emergency switch circuit are closed When the pres sure sen...

Page 11: ...n 11 SSZ RZ3 RZ3B CONTROL UNIT CONNECTION TO MACHINE OPERATING SYSTEM Safe stop by external devices in manual reset Safe stop by intern contacts in manual reset Safe machine stop by external devices i...

Page 12: ...AND SSZ RZ3B UNIT The control unit is provided with an automatic reset function In a pressure sensitive device is released then K1 and K2 relays will immediately return to their baseline position swi...

Page 13: ...nufacturer Any modifications or installations of other components devices in the system shall be prohibited The SSZ control unit shall be the only device suitable for control of SSZ sensitive devices...

Page 14: ...any has for more than 25 years been carrying out internal quality control in its full scope i e including particular elements and their documentation The same team of qualified employees participates...