background image

 

 

 
 
 
 
 
 

Web Application Gateway IGW/935 

with eSOM/3517

First Steps 

SSV Embedded Systems 

Dünenweg 5 
D-30419 Hannover 
Phone:  +49 (0)511/40 000-0 
Fax: 

+49 (0)511/40 000-40 

Email:  [email protected] 

Document Revision: 1.3 

Date: 2018-08-29 

 
 

Summary of Contents for IGW/935

Page 1: ...ation Gateway IGW 935 with eSOM 3517 First Steps SSV Embedded Systems D nenweg 5 D 30419 Hannover Phone 49 0 511 40 000 0 Fax 49 0 511 40 000 40 Email sales ssv embedded de Document Revision 1 3 Date...

Page 2: ...4 Power Supply 8 4 OPERATION 9 4 1 Booting the IGW 935 9 4 2 Accessing the SSV WebUI WebConfig 9 4 3 Accessing the SSV WebUI with DHCP enabled 10 4 4 Firewall Configuration 12 4 5 LAN1 Configuration...

Page 3: ...mentation Plug in power supply DVI HDMI video cable CD ROM for eSOM 3517 Screwdriver 1 2 Required Equipment To operate the IGW 935 the following hardware is required One Ethernet cross over cable or t...

Page 4: ...power supply must provide a stable output voltage between 12 24 VDC 10 The output power should be at least 2 5 W Please pay attention that the power cord or other cables are not squeezed or damaged in...

Page 5: ...gure 1 With two standard Ethernet patch cables over a hub or switch like shown in figure 2 Figure 1 Ethernet link with cross over cable Please note For the Ethernet connection in figure 1 it is requir...

Page 6: ...ion Gateway IGW 935 First Steps 6 Document Revision 1 3 3 2 DVI HDMI Video Link Use the DVI HDMI video cable to connect an external monitor device with the IGW 935 like shown figure 3 Figure 3 DVI HDM...

Page 7: ...port COM1 Terminal Signal A1 COM1 RS485 Serial Port RX TX A2 COM1 RS485 Serial Port RX TX A4 Ground Table 2 Screw terminal COM1 Please note The RS485 officially called TIA EIA 485 A connection betwee...

Page 8: ...sary power like shown in figure 5 Figure 5 Power supply for the IGW 935 Terminal Signal A3 Vin 12 24 VDC 10 A4 GNDin Table 3 Screw terminal power CAUTION Providing the IGW 935 with a higher voltage t...

Page 9: ...s may take up to one minute 4 2 Accessing the SSV WebUI WebConfig To open the login page of the SSV WebUI enter the ex factory IP address and port number of LAN1 of the IGW 936 manually in a web brows...

Page 10: ...pen in Windows Control Panel Network and Internet View network com puters and devices The IGW 935 should show up in this list Figure 7 Selecting the IGW 935 Just right click on the IGW 935 to open the...

Page 11: ...b Application Gateway IGW 935 First Steps Document Revision 1 3 11 Figure 8 The properties dialog shows the current IP address Now you are able to access the IGW 935 via a Telnet client or a web brows...

Page 12: ...3 4 4 Firewall Configuration Choose from the menu Services Firewall and NAT Figure 9 Firewall and NAT settings 1 In the section Firewall configuration enable the checkbox 2 In the section Forwarding...

Page 13: ...om the menu Network LAN1 Figure 10 LAN1 settings To enable the automatic IP address assignment via DHCP follow these steps 1 In the section IP address configuration enable the radio button automatical...

Page 14: ...e current IP address of the IGW 935 in a web browser e g http 192 168 0 126 Figure 11 Demo page of the SSV WebUI The same demo page is visible if an external video monitor is connected to the IGW 935...

Page 15: ...ss of the IGW 935 to activate a Telnet ses sion In the upcoming Telnet window you can login with the username root and the password root Now you can enter any Linux commands which will be executed by...

Page 16: ...file system The default setting of the root file system after the boot process is read only There are on ly three exceptions which are shown in the table 4 Directory Remark flash R W directory non vol...

Page 17: ...ritable and deletable Please pay attention not to damage important system files With the command mount o remount ro the system is set back to the read only initial condition after the boot process Ple...

Page 18: ...ns LxWxH 112 mm x 23 mm x 100 mm Temperature range 0 C 70 C Rel air himudity max 85 7 PINOUT SCREW TERMINALS The table 5 shows the pinout of the screw terminals of the IGW 935 Pin Power RS485 A1 RX TX...

Page 19: ...ake a USB memory stick and format it under Windows with FAT16 or FAT32 4 Create a new simple text file on the memory stick name it factoryreset and re move the file extension Please note Keep in mind...

Page 20: ...ame Review 1 0 2012 12 20 First version WBU HNE 1 1 2013 03 08 Added chapter 4 3 WBU HNE 1 2 2018 06 29 Edited chapter 4 WBU HNE 1 3 2018 08 29 Added chapter 9 WBU HNE The content of this document can...

Reviews: