SST EcoSmart 25 Manual Download Page 10

10

THE ECOSMART 25 THERMOSTAT INSTALLATION 

MANUAL

Scope of delivery
1.

 EcoSmart 25 Thermostat

2.

  Floor temperature sensor with the installation wire (2 m±10%)

3.

 Technical certificate

4.

 Packing box

Factory settings reset

The EcoSmart 25 thermostat can be reset to the factory settings if 

necessary . In this case, information about connected Wi-Fi networks 

will be erased from the device memory heating, schedules and 

temperature settings will be returned to the factory settings:
28 °C – the comfort temperature, 12 °C – the energy saving and freeze 

prevention temperature . Also the constant temperature maintenance 

mode will be set, with the control by the floor temperature sensor (28 

°С) and the limitation by the air temperature sensor (35 °С); and the 

self-learning feature will be enabled . 
To reset the factory settings, remove the lock by pressing and holding 

the “<”and “>” buttons for more than 3 seconds . After that, the display 

of flashing zeros will appear on the thermostat screen and the device 

will return to factory settings . Turn it ON by pressing the central button .

Summary of Contents for EcoSmart 25

Page 1: ...TECHNICAL CERTIFICATE Thermostat EcoSmart 25...

Page 2: ...he EcoSmart 25 thermostat installation manual 10 Scope of delivery 10 Installation and connection 11 Floor temperature sensor installation 12 Thermostat installation 14 Mounting the thermostat 16 Asse...

Page 3: ...y in cluded in the scope of delivery The thermostat can control waterheated floors when using a normally closed thermal head with 230 V control voltage see Figure 5 on page 15 Remote control of heatin...

Page 4: ...tphone use a Wi Fi network The supported Wi Fi network standards are IEEE 802 11 b g n 2 4 GHz The smartphone OS requirements ANDROID 5 1 0 iOS 10 0 Download free SST Cloud Aapp for your smartphone or...

Page 5: ...type of router you are using If the Wi Fi signal level of your home network exceeds the radio interference level by no more than 20 dBm at the location where the thermostat is installed we recommend c...

Page 6: ...e router s position or use equipment to increase the coverage area of the Wi Fi network access point repeater etc Wi Fi signal propagation is affected by reinforced concrete floors metal objects cabin...

Page 7: ...mostat uses an LCD touch display with functional control buttons applied to it To set up and control the device the control buttons are used 1 to decrease the temperature following value 2 3 1 Figure...

Page 8: ...Used sensor floor air The main indication window of the thermostat There are two main display modes of the device current time indication Figure 2a current floor and air temperature indication Figure...

Page 9: ...three seconds the touch buttons are calibrated and then you can modify the device settings The buttons lock automatically 40 seconds after the last press You can force the lock by holding the power b...

Page 10: ...ettings will be returned to the factory settings 28 C the comfort temperature 12 C the energy saving and freeze prevention temperature Also the constant temperature maintenance mode will be set with t...

Page 11: ...ot replace the professional skill of the device installer The manufacturer s guarantee does not cover any product defects caused by mechanical damage improper installation or operation for purposes or...

Page 12: ...this cable Figure 3 At that you can select the parameters of the operating temperature sensors from the list provided in the SST Cloud App Place the tube in preliminarily prepared grove chase in the f...

Page 13: ...0 60 cm The floor temperature sensor is installed when you perform your heating element mat cable section or film installation The thermostat is installed at the end of the warm floor system installat...

Page 14: ...e edergize the supply cable Connect all required wires to the thermostat using its terminals with screw fastening The temperature sensor is connected to terminals 1 and 2 polarity does not matter The...

Page 15: ...heating systems Figure4 Protective earthing line PE External terminal connector N L 230 VAC Temperature sensor Single core heating cable mat Protective earthing line PE External terminal connector N...

Page 16: ...the front cover pulling it slightly out Figure 6a 2 Take off the cover Figure 6b 3 Place the rear part of the device into the mounting box and fasten by means of at least two screws Figure 6a To asse...

Page 17: ...er at an angle up to the click of all latches Make sure that the front cover tightly adjoins the rear part of the thermostat installed in the mounting box Figure 6b To disassemble the device carefully...

Page 18: ...oor temperature sensor included in the scope of delivery TST02 NTC 6 8 kOhm Sensor installation wire length 2 m 10 Permissible ambient air temperature from 5 C to 40 C Permissible relative air humidit...

Page 19: ...retention time 4 hours automatically synchronized when accessing cloud Floor temperature sensor nominal resistance supported can be selected in the SST Cloud App Atlantic NEVADA 6 8 kOhm Aube 10 kOhm...

Page 20: ...transport used SAFETY MEASURES The thermostat conforms to the requirements of the Technical Regulations EN 60730 1 2016 EN 55014 1 2017 EN 61000 3 2 2014 EN 61000 3 3 2013 EN 55014 2 2015 The power co...

Page 21: ...anspor tation rules as well as installation and operation guidelines are observed Guarantee period 3 years from the date of sale During the guarantee period the buyer has the right for repair or repla...

Page 22: ...he manufacturer s service center or its authorized regional representative The Service Center 7 495 728 80 80 garant sst ru 141008 Russia Moscow region Mytischi Proektiruemyj proezd 5274 Bldg 7 Addres...

Page 23: ...23 Passed for printing on 25 05 2020 The thermostat EcoSmart 25 date of manufacture has passed factory tests and is certified as ready for operation QCD stamphere Date of sale Seller s stamp here...

Page 24: ...The manufacturer Zavod SST TP LLC Russia 141008 Mytischy Moscow region Proektiruemyj proezd 5274 Bldg 7 Tel fax 7 495 728 80 80 e mail sst sst ru www sst iwarm com...

Reviews: