SSP HOLDX RL-A1 Operating Manual Download Page 8

  

EN

1 .  Information about this document

1 .1  Function

These operating manual provides all necessary information for the assembly, installation 
and safe operation of the anchor plate. The operating manual must always be readable and 
available during the operating life of the device. Read the operating manual carefully before 
using the device. Always hand this operating manual over to future owners and users of 
the device. Add any supplement received from the manufacturer to the operating manual.

1 .2  Safety instruction for the authorized skilled personnel .

The tasks described in this operating manual may only be carried out by trained skilled 
personnel authorized by the plant owner. You must read and understand the operating 
manual before starting the HOLDX RS/RL-A1/A2 anchor plate. Familiarize yourself with the 
applicable rules and regulations relating to industrial safety and accident prevention. The 
national legislation applies to the assembly, installation and regular technical inspections.

1 .3  Symbols

Caution

If the warnings are not observed, faults or malfunctions as well as injury to 
persons and/or damage of the machines can occur.

Information

Helpful additional information

1 .4  Scope of application

The product described herein has been developed to be a part of an overall system or machine 
for safety-related application in process and automation technology. The manufacturer of 
the plant or machine is responsible for ensuring the correct overall function of the system.
The anchor plate may only be used in accordance with the following versions or for appli-
cations approved by the manufacturer. For detailed information on the application area: see 
Section 2 – Product description.

1 .5  Safety Instructions

Observe the safety instructions in the operating manual, which are identified by above 
symbol for caution or warning. Follow national installation, safety and accident prevention 
regulations. For additional technical information refer to SSP data sheets or visit our website 
at www.safety-products.de. We reserve the right to make technical modifications for reasons 
of improvement.

1 .6  Foreseeable Misuse

Danger to persons or damages to parts of machines or installations can arise as a result 
of inappropriate or incorrect use or manipulation of the anchor plate. Please observe the 
related information in the standard EN ISO 14119. It is prohibited to use with HOLDX 
RS-A1/A2 or HOLDX RL-A1/A2 spare parts or accessories, which have not been expressly 
approved by the manufacturer.

1 .7  Liability Disclaimer

We accept no liability for damages or operational malfunctions resulting from improper 
installation or failure to comply with this operating manual. No other liability is accepted 
by the manufacturer for damages resulting from use of spare parts or accessories, which 
have not been approved by the manufacturer. Any unauthorized repairs, reconstructions and 
modifications are not permitted for safety reasons and rule out liability of the manufacturer 
for resulting damages.

2 .  Product Description

2 .1  Intended use

The HOLDX RS-A1/A2 or HOLX RL-A1/A2 anchor plates are intended exclusively for use with 
the process locks HOLDX RS1/2 (short design) or HOLDX RL1/2 (long design).

2 .2  Design types

This operating manual is valid for the following design types:

Type code HOLDX R

- A

Design

short design

long design

Grid

fixed grid 50 N 

(permanent process lock with permanent magnet)

without fixed grid 

(without permanent magnet)

Example:

HOLDX RS-A1 

Anchor plate for HOLDX RS1/2 (short design) 

 

with fixed grid 50 N (permanent process lock with permanent magnet)  

HOLDX RL-A2 

Anchor plate for HOLDX RL1/2 (long design) 

 

without fixed grid (without permanent magnet)

2 .3  Technical data

Ambient conditions

Operating temperature min./max.  

-25 ... + 55°C

Storage temperature min./max.  

-25 ... + 70°C

Degree of contamination  

2

Protection class 

  IP67 

Mechanical data

Permanent latching force   

50 N

Smart latching force (adjustable with HOLDX Manager)  

0 / 30 N / 50 N  

Dimensions 
Anchor plate RS-A1/A2
Width  

45 (35) mm

Length  

108.5 mm

Height 

17.5 mm

Weight 

125 kg 

Anchor plate RL-A1/A2
Width 

34 mm

Length 

214.4 mm

Height 

20.1 mm

Weight 

475 kg 

Torque (mounting screw) anchor plate 

 6 Nm

Fastening 

screwed connection with pan-head screws M6 Torx with pin (countersunk) 

Strength class  

min. A2/70 (yield strength > 450N/mm² and  

tensile strength > 700N/mm² fixing with medium-strength threadlocker,

e.g. Loctite 243 Anchor plate housing materials RS-A1/

A2 

PBT GF30, PA GF 46, S235 nickel-plated, Poron

Anchor plate housing materials RL-A1/A2  

PBT GF30, S235 nickel-plated

Shock resistance 

 30 g / 11 ms  

Vibration resistance  

10 to 150 Hz, 1 g, 55 Hz 3 x 30 min

Summary of Contents for HOLDX RL-A1

Page 1: ...Montage 3 3 1 Abmessungen 3 3 2 Allgemeine Montagehinweise 3 3 3 Anfahrtsrichtungen und Ausrichtung 4 3 4 Montage der Ankerplatten HOLDX RL A1 A2 5 3 5 Montage der Ankerplatten HOLDX RS A1 A2 5 4 EG...

Page 2: ...ndung oder Manipu lation k nnen durch den Einsatz der Ankerplatten Gefahren f r Personen oder Sch den an Maschinen bzw Anlagenteilen nicht ausgeschlossen werden Bitte beachten Sie auch die diesbez gli...

Page 3: ...ist durch geeignete Ma nahmen Verwendung von Einwegschrauben Verkleben Aufbohren von Schraubenk pfen Verstiften an der Schutzeinrichtung unl sbar zu befestigen und gegen Verschieben zu sichern Um ein...

Page 4: ...4 DE 3 3 Anfahrtsrichtungen und Ausrichtung Abb 3 HOLDX RS1 2 mit Ankerplatte RS A1 A2 Abb 4 HOLDX RL1 2 mit Ankerplatte RL A1 A2...

Page 5: ...tage der Ankerplatten HOLDX RS A1 A2 Abb 8 Montage an Drehfl gelt ren Ankerplatte an Monta geplatteanbringenundSchraubenM6x8mmTorxfestziehen Abb 9 Montageplatte mitAnkerplatte am Profil anbringen undz...

Page 6: ...U RED Richtlinie 2014 30 EU EMV 2014 65 EU RoHS Angewandte Normen EN ISO 13849 1 2015 EN IEC 62061 2015 EN ISO 14119 2013 EN 60947 5 3 2013 EN 300 330 V2 1 1 EN 55011 2009 A1 2010 EN 61326 3 1 2008 Be...

Page 7: ...on 9 3 1 Dimensions 9 3 2 General installations notes 9 3 3 Directions and alignment 10 3 4 Mounting the HOLDX RL A1 A2 anchor plates 11 3 5 Mounting the HOLDX RS A1 A2 anchor plates 11 4 EC Declarati...

Page 8: ...s a result of inappropriate or incorrect use or manipulation of the anchor plate Please observe the related information in the standard EN ISO 14119 It is prohibited to use with HOLDX RS A1 A2 or HOLD...

Page 9: ...device The anchor plate must be permanently installed to the protective device by suitable mea sures use of one way screws gluing drilling of screw heads pinning and secured against displacement To a...

Page 10: ...10 EN 3 3 Directions and alignment Fig 3 HOLDX RS1 2 with anchor plate RS A1 A2 Fig 4 HOLDX RL1 2 with anchor plate RL A1 A2...

Page 11: ...m 3 5 Mounting the HOLDX RS A1 A2 anchor plates Fig 8 Installationonswingdoors Attachtheanchorplateto the mounting plate and tighten theTorx screws M6 x 8 mm Fig 9 Attach the mounting plate with the a...

Page 12: ...Directive 2014 53 EU RED Directive 2014 30 EU EMC 2014 65 EU RoHS Applied standards EN ISO 13849 1 2015 EN IEC 62061 2015 EN ISO 14119 2013 EN 60947 5 3 2013 EN 300 330 V2 1 1 EN 55011 2009 A1 2010 E...

Reviews: