background image

EN 

 11

3 .4  Mounting the HOLDX RL-A1/A2 anchor plates

Fig. 5:  Installation on swing doors: Attach the anchor plate to 
the mounting plate and tighten the Torx screws M6 x 8 mm.

Fig. 6:  Attach the mounting plate with the anchor plate to 
the profi le and align with the process lock. Tighten the Torx 
screws M8 x 12 mm.

Fig. 7:  Installation on sliding doors: Attach the anchor plate 
to the profi le of the sliding door and align it with the process 
lock. Tighten the Torx screws M6 x 10 mm.

3 .5  Mounting the HOLDX RS-A1/A2 anchor plates

Fig. 8:  Installation on swing doors: Attach the anchor plate to 
the mounting plate and tighten the Torx screws M6 x 8 mm.

Fig. 9:  Attach the mounting plate with the anchor plate to 
the profi le and align with the process lock. Tighten the Torx 
screws M8 x 12 mm.

Fig. 10:  Installation on sliding doors: Attach the anchor plate 
to the profi le of the sliding door and align it with the process 
lock. Tighten the Torx screws M6 x 10 mm.

All screws used are Torx pan-head screws with countersunk pin (safety screws) of strength class A2/70 and are tightened to 6 Nm. Securing from loosening with a medium-strength 
threadlocker, e.g. Loctite 243.

Summary of Contents for HOLDX RL-A1

Page 1: ...Montage 3 3 1 Abmessungen 3 3 2 Allgemeine Montagehinweise 3 3 3 Anfahrtsrichtungen und Ausrichtung 4 3 4 Montage der Ankerplatten HOLDX RL A1 A2 5 3 5 Montage der Ankerplatten HOLDX RS A1 A2 5 4 EG...

Page 2: ...ndung oder Manipu lation k nnen durch den Einsatz der Ankerplatten Gefahren f r Personen oder Sch den an Maschinen bzw Anlagenteilen nicht ausgeschlossen werden Bitte beachten Sie auch die diesbez gli...

Page 3: ...ist durch geeignete Ma nahmen Verwendung von Einwegschrauben Verkleben Aufbohren von Schraubenk pfen Verstiften an der Schutzeinrichtung unl sbar zu befestigen und gegen Verschieben zu sichern Um ein...

Page 4: ...4 DE 3 3 Anfahrtsrichtungen und Ausrichtung Abb 3 HOLDX RS1 2 mit Ankerplatte RS A1 A2 Abb 4 HOLDX RL1 2 mit Ankerplatte RL A1 A2...

Page 5: ...tage der Ankerplatten HOLDX RS A1 A2 Abb 8 Montage an Drehfl gelt ren Ankerplatte an Monta geplatteanbringenundSchraubenM6x8mmTorxfestziehen Abb 9 Montageplatte mitAnkerplatte am Profil anbringen undz...

Page 6: ...U RED Richtlinie 2014 30 EU EMV 2014 65 EU RoHS Angewandte Normen EN ISO 13849 1 2015 EN IEC 62061 2015 EN ISO 14119 2013 EN 60947 5 3 2013 EN 300 330 V2 1 1 EN 55011 2009 A1 2010 EN 61326 3 1 2008 Be...

Page 7: ...on 9 3 1 Dimensions 9 3 2 General installations notes 9 3 3 Directions and alignment 10 3 4 Mounting the HOLDX RL A1 A2 anchor plates 11 3 5 Mounting the HOLDX RS A1 A2 anchor plates 11 4 EC Declarati...

Page 8: ...s a result of inappropriate or incorrect use or manipulation of the anchor plate Please observe the related information in the standard EN ISO 14119 It is prohibited to use with HOLDX RS A1 A2 or HOLD...

Page 9: ...device The anchor plate must be permanently installed to the protective device by suitable mea sures use of one way screws gluing drilling of screw heads pinning and secured against displacement To a...

Page 10: ...10 EN 3 3 Directions and alignment Fig 3 HOLDX RS1 2 with anchor plate RS A1 A2 Fig 4 HOLDX RL1 2 with anchor plate RL A1 A2...

Page 11: ...m 3 5 Mounting the HOLDX RS A1 A2 anchor plates Fig 8 Installationonswingdoors Attachtheanchorplateto the mounting plate and tighten theTorx screws M6 x 8 mm Fig 9 Attach the mounting plate with the a...

Page 12: ...Directive 2014 53 EU RED Directive 2014 30 EU EMC 2014 65 EU RoHS Applied standards EN ISO 13849 1 2015 EN IEC 62061 2015 EN ISO 14119 2013 EN 60947 5 3 2013 EN 300 330 V2 1 1 EN 55011 2009 A1 2010 E...

Reviews: