background image

 

1 .  About This Document

1 .1  Function

This operating manual provides all necessary information for the assembly, installation, safe 
operation and disassembly of the emergency stop/emergency stop button EDI. The operating 
manual must always be readable and available during the operating life of the device. 
Read the operating manual carefully before using the device. Always hand this operating 
manual over to future owners and users of the device. Add any supplement received from 
the manufacturer to the operating manual.

1 .2  Safety instruction for the authorized skilled personnel .

The tasks described in this operating manual may only be carried out by trained skilled 
personnel authorized by the plant owner. You must read and understand the operating 
manual before starting the EDI. Familiarize yourself with the applicable rules and regulations 
relating to industrial safety and accident prevention. National and international legislation 
apply to assembly, installation and regular technical inspections.

1 .3  Symbols

Caution

If the warnings are not observed, faults or malfunctions as well as injury to 
persons and/or damage of the machines can occur.

Information

Helpful additional information

1 .4  Scope of application

The emergency stop/emergency off buttons EDI are electromechanical switching devices for 
the protection of persons working with or near machines. They are used to stop/shut down 
machines and plants in order to avoid or reduce arising or existing dangers to persons as 
well as damages to the machine or workpieces. The manufacturer of the plant or machine 
is responsible for ensuring the correct overall function of the system.

1 .5  Attention: Safety Instructions

Observe the safety instructions in the operating manual, which are identified by an above 
symbol for caution or warning. Follow national installation, safety and accident prevention 
regulations. For additional technical information refer to SSP data sheets or visit our website 
at www.safety-products.de.
All information is supplied without liability. We reserve the right to make technical mod-
ifications for reasons of improvement. No remaining risks are known, if the safety notes 
and instructions regarding assembly, installation, operation and maintenance are followed.
Disconnect the plant and the device from the power supply before starting installation. 
Emergency stop/emergency off buttons are used to protect personnel. Improper installation 
or manipulation may cause serious injury to persons and must not be bypassed, removed 
or otherwise rendered ineffective.

1 .6  Attention: Incorrect use

Danger to persons or damages to parts of machines or installations can arise as a result of 
inappropriate or incorrect use or manipulation of the process guard locking. 
The emergency stop/emergency off function must not be used as a substitute for protective 
measures or other safety functions, but should be designed as a supplementary protective 
measure. Furthermore, the effectiveness of protective devices or devices with other safety 
functions must not be impaired. Using his risk analysis, the designer must ensure that the 
emergency stop/emergency off button in combination with the controller reaches the required 
safety level (SIL, SILCL or PL).

1 .7  Liability Disclaimer

We accept no liability for damages or operational malfunctions resulting from improper 
installation or failure to comply with this operating manual. No other liability is accepted 
by the manufacturer for damages resulting from use of spare parts or accessories, which 
have not been approved by the manufacturer. Any unauthorized repairs, reconstructions and 
modifications are not permitted for safety reasons and rule out liability of the manufacturer 
for resulting damages.

2 .  Product Description

2 .1  Intended Use

The device can only be used in industrial applications.

2 .2  Design types

The EDI emergency stop/emergency off button in slimline housing with an M12 connector 
(according to EN 61076-2-101) is available in various versions.
• 

Emergency stop button, not illuminable

• 

Emergency stop button, illuminable

• 

Emergency stop button, not illuminable with reset button, illuminable

• 

Operational unit with 2 buttons, illuminable red/green

• 

Operational unit with reset button, illuminable

This operating manual is valid for the following design types:
EDI B7B 

emergency stop button illuminated white 8-pole 

SP-G-61-000-01

EDI B7 

emergency stop button standard 4-pole 

SP-G-61-000-02

EDI B7S 

stop button black head 4-pole 

SP-G-61-000-03

EDI C7 

emergency stop reset button illuminated 8-pole  SP-G-61-000-04

EDI E1B 

operational unit, 2 buttons - illuminated red/green 8-pole  SP-G-61-000-05

EDI D1B 

operational unit with reset button illuminated 4-pole 

SP-G-61-000-09

2 .3  Scope of application and mode of action

National and international legislation apply to assembly, commissioning and regular technical 
inspections, in particular
•  Machinery Directive 2006/42/EC
•  Low Voltage Directive 2014/30/EU
•  Safety regulations
•  Accident prevention regulations & safety rules
Manufacturers and operators of machines with emergency stop/emergency off buttons are 
responsible for observing the operating manual as well as applicable safety regulations 
and rules.
For intended use, the relevant requirements for the installation and operation of emergency 
stop/emergency off buttons must be observed.
•  EN 60204-1:2006
•  EN 13849-1/-2:2008
•  EN ISO 13850:2015 (D)

2 .4  Product characteristics

Built-in version or surface-mounted version with two-part surface-mounting housing. 
Unlocking by rotary movement to the left or right or only to the right.
Connection of the contact blocks via spring-loaded terminal (quick connection), screw 
connection or M12 plug connector.

2 .5  Dimensions

Dimensions in mm

108,6

40

36,3

14,6

24

M

12

52,3

Ø

28

EDI B7, EDI B7B

Reviews: