SSI PRL-1600 Technical Manual Download Page 10

SOLID STATE INSTRUMENTS

INSTRUCTION SHEET

PRT-16 PULSE TRANSMITTER BASE

GND

Y2
Y1

K

NEU

120V

Input #1

POWER SUPPLY
INPUT

MOUNTING POSITION -

 The PRT-16 Base unit may be mounted in any position.

POWER INPUT -

 For 120VAC, connect the "hot" lead to the 

L1

 power supply terminal.  Connect the neutral lead

to the 

NEU

 terminal.  For a power supply voltage between 208 and 277 VAC, connect the "hot" lead to the 

L2

power supply terminal and the neutral lead to the 

NEU

 terminal. Use EITHER L1 or L2 for the appropriate

voltage input but not both.  Connect the 

GND

 terminal to Ground.

METER CONNECTIONS -

 Form A (2W) mode: Connect the PRT-12's "K" and "Y

1

" input terminals to meter's

"K" and "Y" terminals. The "Yx" input terminals are "pulled-up" to +13VDC power supply, making it compatible
with open-collector transistor meter outputs, as well as all non-polarized mechanical or solid state pulse outputs.
Form C (3W) mode:  Connect the PRT-16's "K", the "Y

1

" and the "Z

1

" input terminals to the meter's "K", "Y" and

"Z" terminals.  The PRT-16's "K" terminal is the system common (return).

Common return from meter

277V

Revision: 4/10/22

To PRNT-1600

Transmitter Radio/

Antenna Unit

L2

L1

N

G

Kin

Y1in

Z1in

INPUT CONFIGURATION -

 The PRT-16 accepts either 2 Form "C" (3-Wire) inputs using the K, Y & Z input

terminals, or 4 Form "A" (2-Wire) inputs using the K & Y and K & Z terminals. See Dip Switch Definitions and
Settings.

Y4
Y3

Y2in

Z2in

SCK-

SDI+

SDI-

SCK+

+V

GND

24AWG (min)/8-conductor (4-twisted pairs)
with shield 100' max. See Page 8.

OUTPUT TO PRNT-1600 TRANSMITTER/ANTENNA UNIT -

 Connect the 8-conductor (4-TWISTED PAIRS)

24AWG(min) shielded control cable to the PRNT-1600 Transmitter/Antenna Unit.  For best results, it is advisable
to keep this length of this cable to the minimum practical distance.

BR/W

OR/W

BRN

ORG

GR/W

GRN

BL/W

BLU

1

2

3

4

5

6

7

SHLD

SVR

8

9

SDO+

SDO-

TB2

TB1

a division of Brayden Automation Corp.

6230 Aviation Circle, Loveland, Colorado 80538

Phone: (970)461-9600

E-mail: [email protected]

ENCLOSURE -

 The PRT-16 base unit is housed in a polycarbonate base and cover and is designed to be

mounted into another electrical enclosure suitable for the application.  Optional NEMA 3R or NEMA 4X outdoor
enclosures are available.

Wire

Function

Wire

Color

10

Input #2

Input #3

Input #4

2 Meters'
KYZ (3W)
outputs

K

Z

K

Y

K

Z

K

Y

3W

2W

4 Meters'
KY (2W)
outputs

K

Y

K

Y

K

Y

K

Y

Summary of Contents for PRL-1600

Page 1: ...s Pulse Link System Technical Manual Solid State Instruments A division of Brayden Automation Corporation 6230 Aviation Circle Loveland CO USA 80538 970 461 9600 e mail support brayden com Revision A1...

Page 2: ...roduction PRNT 1600 Pulse Radio Transmitter PRT 16 Transmitter Base Unit Using the 2 Wire Form A or 3 Wire Form C Modes PRNR 1600 Pulse Radio Receiver PRR 16 Receiver Base Unit Troubleshooting and Tec...

Page 3: ...cycle The Receiver will then generate the correct number of pulses at KYZ outputs over the next 10 seconds The PRNT 1600 Transmitter Antenna Unit contains the transceiver radio a microcontroller and a...

Page 4: ...n one of the channel frequencies until they are received by the receiver Set the Transmitter and the Receiver to the same channel number Multiple PRL 1600 systems can operate in the same radio airspac...

Page 5: ...cars trucks buses or any other obstruction that gets in the line of sight between the transmitter and receiver at any time Interruptions in the line of sight may cause pulses to be lost Generally spe...

Page 6: ...ctors being careful not to cut the insulation of the conductors or any strands of the shield s drain wire Strip the insulation of each conductor back 1 4 Connect each conductor of the cable to the 9 p...

Page 7: ...Scale 8 Conductor 4 Twisted Pairs 24AWG Control Cable with shield 100 max POWER INPUT The PRNT 1600 receives its power supply from the PRT 16 Transmitter Base unit NOTICE TO USER FCC ID TIT PRT 1600 T...

Page 8: ...2 3 4 5 6 7 8 9 TB1 Transmitter Antenna PCB Assembly LED1 PRNT 1600 Wire Connection Assignments 1 3 2 4 6 5 7 8 9 Terminal Pair 1B 2A 2B 3A 3B 1A 4A 4B ORG WHT ORG GRN WHT BLU WHT BLU GRN BRN WHT SILV...

Page 9: ...e K common and a Y input Four independent 2 Wire meter pulse channels can be transmitted Set Switch 7 to the DOWN position for the Form A mode and UP for Form C mode Switch 8 Pairing the Transmitter a...

Page 10: ...meter 277V Revision 4 10 22 To PRNT 1600 Transmitter Radio Antenna Unit L2 L1 N G Kin Y1in Z1in INPUT CONFIGURATION The PRT 16 accepts either 2 Form C 3 Wire inputs using the K Y Z input terminals or...

Page 11: ...he conductors or any strands of the shield s drain wire Strip the insulation of each conductor back 1 4 Connect each conductor of the cable to the 9 position connector TB1 using a small flat blade scr...

Page 12: ...harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or...

Page 13: ...ch 4 Not used Switch 5 Fixed Pulse Width Sets the output pulse width to 50mS DOWN or 100mS UP when in Form A mode Switch 6 Not used RSSI Indicator The receiver has an Signal Strength Indicator to show...

Page 14: ...o the NEU terminal Connect the GND terminal to Ground GROUND MUST BE CONNECTED TO A GOOD ELECTRICAL SYSTEM GROUND SIGNAL INPUT The PRNR 1600 receiver antenna unit connects to the 9 position connector...

Page 15: ...2 3 4 5 6 7 8 9 TB1 Transmitter Antenna PCB Assembly LED1 Wire Connection Assignments 1 3 2 4 6 5 7 8 9 Terminal Pair 1B 2A 2B 3A 3B 1A 4A 4B ORG WHT ORG GRN WHT BLU WHT BLU GRN BRN WHT SILVER BRN BR...

Page 16: ...ving downstream device or by an auxiliary power supply The outputs are solid state and are non polarized They may be used for AC or DC voltages The output is limited to 100mA 250VAC 800mW maximum Fuse...

Page 17: ...r the transmitter and receiver respectively 2 Set Dip Switch 8 on both the transmitter and receiver to the UP position to put the system in the Learn mode 3 Turn on power to the PRR 1600 Receiver The...

Page 18: ...r to the transmitter s input Set both the transmitter and receiver to Form C by setting Dip Switch 6 to the UP position Using two wires K and Y on a Form C output is acceptable 2 Dip Switch 8 must be...

Page 19: ...THING 3 Mount the Transmitter or Receiver Radio Antenna units as high up off the ground as reasonably possible to prevent RF reflections from the ground This will increase range and reliability and al...

Page 20: ...ly to all components Check the RED LED on the Transmitter and Receiver Antenna boards and make sure they are flashing in fast mode Check to make sure that all Transmitter and Receiver units are both o...

Page 21: ...Appendix A PRT 1600 Dip Switch Settings and LED Indicators 21...

Page 22: ...Appendix B PRR 1600 Dip Switch Settings and LED Indicators 22...

Page 23: ...r there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turn...