SSD Statiron DZ4 Instruction Manual Download Page 11

Specifications 

 

Signal detection method 

Oscillating chopper method 

Display refresh frequency

 

 

0.5 seconds

 

 

Measurable potential range 

Normal mode: 0.00 - ±19.99kV (resolution: 0.01kV)

   

 

 

I.B mode: 0.000 - ±1.999kV (resolution: 0.001kV) 

Continuous operating limit 

Approximately 10 hours (with alkaline battery) 

Measuring distance 

30 mm (between object being measured and sensor) 

Measuring distance adjustment 

Red LED beam focusing method

 

 

Sensor head rotation angle 

180° (stops every 45°) 

Display 

LCD display with built-in backlight

 

 

Polarity display

 

 

  polarity/

  polarity display 

Mode switching

 

 

Switch modes by pressing MODE button 

Battery check

 

 

Remaining charge displayed in display panel

 

 

Battery 

DC9V alkaline rectangular dry cell battery 006P 

Operating  temperature/  humidity 
range 

0 - +40

, 20 - 70

RH, non-condensing

 

 

Dimensions

 

 

68 mm x 22 mm x 138 mm (W x D x H) 

Weight

 

 

Approximately 230g (including battery) 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Statiron DZ4

Page 1: ...lectrical potential meter with digital readout for measuring the electrical potential of charged objects When measuring fluctuating static electricity you can temporarily hold an indicated value and c...

Page 2: ...osed to water or oil Maintenance Regularly remove any built up dirt etc from the optional ion balance plate Built up dirt can cause insulation faults Make sure to turn the main power of the device OFF...

Page 3: ...using it for the first time Instruction manual warranty x 1 this document Main Device Earth Lead x 1 Strap x 1 Battery 006P type 9V alkaline dry cell battery x 1 Soft case Model number ODZ4 SFTCS x 1...

Page 4: ...al changes according to the field strength concentrated in the electrode of the sensor portion of the meter and the size of the charged object In particular if the charged object is smaller than the t...

Page 5: ...ad to a grounded object To obtain accurate measurements the earth terminal must be grounded Measurement Procedure Measuring Static Electricity 1 Turn the meter on Press the POWER button for more than...

Page 6: ...re 3 Fig 3 Red LED mark NOTE If the recommended measuring distance of 30mm cannot be attained do not bring the meter any closer if the potential displayed exceeds 19 99kV Doing so may cause damage to...

Page 7: ...e the I B mode 3 Zero point adjust the meter Point the sensor at a grounded object and press the 0ADJ button NOTE Zero point adjustment is reset when you turn the meter off 4 Attach the ion balance pl...

Page 8: ...s occurs stop measuring immediately as this may cause damage to the meter 7 The value on the display panel is the measurement result unit kV 8 In I B mode you can temporarily hold the measured value b...

Page 9: ...ed on the upper right of the display panel When the battery charge icon shows one unit left replace the battery Error Display The signal detection method of the meter is an oscillating chopper method...

Page 10: ...correct Remedy 1 Perform zero point adjustment again Cause 2 Structural components close to the sensor are charged Remedy 2 Wait until the charge in the components has attenuated The display does not...

Page 11: ...measured and sensor Measuring distance adjustment Red LED beam focusing method Sensor head rotation angle 180 stops every 45 Display LCD display with built in backlight Polarity display polarity pola...

Page 12: ...where you purchased the product SHISHIDO ELECTROSTATIC LTD http www shishido esd co jp HEAD OFFICE MARUNOUCHI BLDG 9F 918 4 1 MARUNOUCHI 2 CHOME CHIYODA KU TOKYO 100 6309 SALES DEPARTMENT TOKYO BRANCH...

Reviews: