background image

Page 5

SENSOR: SETTINGS & CALIBRATION 

(CONTINUED)

OTHER TEMP SENSOR OPTIONS

 

Input type 

Name 

Set 

Value 

Input Temperature Setup Range 

Platinum resis- 

tance ther- 

mometer input 

type 

Platinum 

resistance 

thermometer 

Pt100 



JPt100 


 

Input type 

Name 

Set 

Value 

Input Temperature Setup Range 

Thermocouple 

input type 

Thermocouple  K 


 

 

 

 

 

 

17 

 

 

 

 

 

18 

 

 

 

10 

 

11 

 

Infrared 

12 

 

temperature 

13 

 

sensor 

14 

 

ES1A 

 

 

15 

Summary of Contents for FTSs Pro

Page 1: ...ENGINEERING BETTER BEER FTSs Pro Modular Temperature Controller Europe ...

Page 2: ... by using a temperature sensor to read the present value PV of your vessel and triggering an output based on the set value SV in order to match PV with SV When cooling is called for the solenoid valve will open to allow the flow of glycol through your vessel s cooling jackets or coils until the set value is achieved INTRODUCTION Temperature OFF Run Crash FTSs Pro Controller Solenoid Valve ...

Page 3: ...r comes with a lead marked Sensor The two wires in this cable red and black will connect to your temperature sensor If you are using an Ss Brewtech vessel your tank comes equipped with a PT100 platinum resistance thermometer The red and black wires will connect to terminals 1 and 2 on the thermometer s plug The orientation of the wires does not matter as long as they are connected to terminals 1 a...

Page 4: ...return to the primary display The input setting can be manipulated based on the type of sensor being used The correct input setting for a PT100 sensor is Cn t 1 This should be the default setting on your controller If you are reading a sensor error message S ERR double check your connections to the sensor and ensure that Cn t is set to 1 If you are using a different type of sensor see the included...

Page 5: ...erature Setup Range Platinum resis tance ther mometer input type Platinum resistance thermometer Pt100 0 1 2 JPt100 3 4 Input type Name Set Value Input Temperature Setup Range Thermocouple input type Thermocouple K 0 1 J 2 3 T 4 17 E 5 L 6 U 7 18 N 8 R 9 S 10 B 11 Infrared 12 temperature 13 sensor 14 ES1A 15 ...

Page 6: ... water mixture it should read 32 F 0 C Perform the ice method of calibration and document the offset if any You can then set a temperature offset on the controller to reflect this variation Press the Level Key for less than 1 second and then use the Mode Key until you see Cn5 Next use the Up or Down Key to change the temperature offset Press the Level Key for less than 1 second to exit to the main...

Page 7: ...then press the Mode Key until you see d U Press the Up or Down Keys to toggle between Fahrenheit F and Celsius C The FTSs Pro Modular Temperature Controller allows you to set a hysteresis value This value represents the number of degrees away from the set value that the Omron will trigger an output Press the Level Key for 3 or more seconds and then press the Mode Key until you see HYS Press the Up...

Page 8: ... if you wish to have finer temperature control or if you are using a smaller hysteresis value Press and hold the Level Key for less than 1 second and then press the Mode Key until you see dP Use the Up or Down Keys to move the decimal points Press the Level Key for less than 1 second to exit Up Key Level Key Down Key Mode Key No 1 Display No 2 Display ...

Page 9: ...ontroller and the solenoid valve will open When the set value is achieved OUT will disappear from the display and the solenoid valve will close When in Crash mode the user can quickly toggle to a programmable crash temperature 0 C for example The controller will memorize this temperature and by simply turning the switch you can switch to this temperature without toggling the up and down keys Tempe...

Page 10: ...REV 04182019 SsBrewtech com ...

Reviews: