47
Damper Installation
RC:
Install the compression adjuster knob onto the top cap with the tab
in the forward, unlocked, position.
Install and tighten the retaining screw.
RCT R:
Install the cable stop collar with the housing guide in the
6 o'clock forward position, angled ≈20° degrees from center.
Push the low speed adjuster knob spring retainer (A) in and push the
knob out of the remote spool.
Remove the top cap seal.
Clean each part.
RC
2 mm
1.2 N·m (10 in-lb)
3b
RCT R
87°
20°
A