CLEANING and DISINFECTING 

 

CLEANING 

To clean the display / user interface and other scale contact areas: 

 

Use a soft cloth dampened with water and mild detergent to clean scale surfaces. 

 

Wipe surface with clean soft cloth dampened with water and then dry with clean soft cloth.  

 

Do  not  use  abrasive  materials  to  clean  scale  surface  to  prevent  damage  to  the  surface 
finish. 

 

Do not spray liquid directly onto scale surfaces.  Use only a damp cloth. 

 

DISINFECTION 

To disinfect the display / user interface and other scale contact areas: 

 

Use a soft cloth dampened with disinfectant or a damp disposable disinfectant cloth.  Cloth 

cannot  be  dripping  wet.    Follow  manufacturer’s  instruction  on  the  proper  use  of 
commercially available disinfectants.  

 

Disinfectant solutions with 1% sodium hypochlorite or 70% isopropyl alcohol are suitable 
for display / user interface and other scale contact surfaces. 

 

After  disinfecting,  use  a  soft  cloth  dampened  with  clean  water  and  dry  with  a  soft  clean 
cloth to prevent buildup of material on scale finish. 

 

Do  not  use  abrasive  material  to  disinfect  /  clean  scale  surfaces  to  prevent  damage  to the 
surface finish. 

 

Do not spray liquid directly onto scale surfaces.  Use only a damp cloth.  

 

WARNING:

 

DO  NOT  SPRAY  CLEANING  SOLUTION  OR  LIQUIDS  DIRECTLY 
ON SURFACES TO BE CLEANED

 

WARNING:  EXPOSURE  TO  EXCESSIVE  LIQUID  WILL  DAMAGE  USER 

INTERFACE KEYPAD. 

 

WARNING:

 

DO  NOT 

USE  PRESSURIZED  WATER  OR  STEAM.  THE  SCALE 

SYSTEM CONTAINS ELECTRONIC COMPONENTS THAT MAY BE 

ADVERSELY  AFFECTED  BY  EXPOSURE  TO  SUCH  AN 

ENVIRONMENT. 

Summary of Contents for SR Scales SRV947-BT

Page 1: ...0429 Page 1 of 16 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2022 S Instruments Inc S by S Instru...

Page 2: ...4 SYSTEM DESCRIPTION AND INTENDED USE 5 STORAGE AND TRANSPORTATION 5 CLEANING AND DISINFECTING 6 SPECIFICATIONS 7 BUTTON FUNCTIONS 8 BASIC SYSTEM OPERATION 9 BATTERY REPLACEMENT 9 PAIRING TO BLUETOOT...

Page 3: ...Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2022 S Instruments Inc PACKING CHECKLIST Model SRV947 BT Portable Platform Scale...

Page 4: ...ments Inc ASSEMBLY To install included six 6 AA 1 5 volt alkaline batteries follow steps below STEP 1 Unlatch tab on the Battery Compartment cover on bottom of scale Figure 2 STEP 2 Insert batteries a...

Page 5: ...lograms The SRV947 BT Platform scale is equipped with a Bluetooth wireless module By waking the scale up with the WEIGH button the wireless feature is turned on Then use the free SR Scales app Google...

Page 6: ...tact areas Use a soft cloth dampened with disinfectant or a damp disposable disinfectant cloth Cloth cannot be dripping wet Follow manufacturer s instruction on the proper use of commercially availabl...

Page 7: ...ange AUTO ZERO One button operation AUTO POWER DOWN Approximately 300 seconds AVERAGING Automatic digital filter POWER SUPPLY Six 6 AA 1 5 volt alkaline batteries CALIBRATION Calibration is traceable...

Page 8: ...during this procedure The display will read 0 0 LB or KG The button also wakes up the display and shows the animal s weight if it should Auto Power Down before the weighing process is done HOLD RECAL...

Page 9: ...ing surface remains active If scale shuts down press the ZERO WEIGH button once to wake display and take reading HOLD RECALL The scale display is designed to automatically lock the reading on the disp...

Page 10: ...s listed on the Calibration Form 4 Select the appropriate device and select pair 5 Open the SR Scales application Press the three dots in the upper right hand corner Figure 4A and select Connect a dev...

Page 11: ...for remote wireless operation Use your Android device to display weight and control the SRV947 BT scale functions Figure 5 Ensure your remote display indicates CONNECTED before use The WEIGH button w...

Page 12: ...WEIGH button STEP 3 Place the first calibrated weight on the scale Wait for scale to stabilize note scale reading Remove weight STEP 4 Place second calibrated weight on scale Wait for scale to stabil...

Page 13: ...GH button to turn the scale on STEP 3 Press Lb Kg button and toggle to select lb STEP 4 Press the Calibration button on rear of display Display will read CAL STEP 5 Toggle the ZERO WEIGH button to rea...

Page 14: ...NUMBER STEP 11 When display reads SAVE press the HOLD RECALL button to cycle through Savd and return to CAL STEP 12 Calibration is completed Press the left button on rear of display to return to run...

Page 15: ...ns or liabilities on SR Instruments Inc s part and it neither assumes nor authorizes any other person to assume for SR Instruments Inc any other liabilities in connection with the sale of said article...

Page 16: ...nual Part No MAN947 BT_220429 Page 16 of 16 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2022 S Ins...

Reviews: