Battery life for all sample  rates and compression methods (Zinc-Air battery, type ZA675) 
 

  Sample rate 

None 

ULaw 

4bit 

ADPCM 

2bit 

ADPCM 

  5,5kHz 

85 

85 

75 

82 

8kHz 

70 

73 

60 

70 

11kHz 

57 

67 

45 

60 

16kHz 

43 

52 

31 

36 

22kHz 

26 

28 

 
Battery life for all sample rates and compression methods (alkaline battery, type AG13) 
 

  Sample rate 

None 

uLaw 

4bit 

ADPCM 

2bit 

ADPCM 

  5,5kHz 

19 

19 

12 

12 

8kHz 

12 

12 

12 

11 

11kHz 

10 

10 

10 

16kHz 

22kHz 

 
Operating instructions 

 
For  controlling  all  functions  is  used  one  operating  button  and  multifunctional  LED.  This 
button works in single click mode, where each click must be at least 3 seconds long. In case 
of  selecting  optional  double  click  mode,  it  requires  one  click  in  length  of  at least  3 seconds 
followed by pause in length of 1 second and second same click again.  
 
When  the  battery  is  inserted,  one  short  LED flash must follow after about 5 seconds. If this 
single  flash  is  not  observed,  use  fresh  battery  instead  of  partly  discharged  or  check  battery 
contacts.  
 

Start and stop the recording 

 
Using  operating  button  activates  those  actions.  Before the recording starts, the LED flashing 
sequence  will  follow.  When  it  flashes  only  ones,  the  memory  is  full  and  recording  can’t  be 
started. Flashing 2 to 4 times indicates available memory space. (4 flashes – more than 75% 
space available, 3 flashes – more than 50% space available, 2 flashes – less than 25% space 
available).    The  recorder  should  store  up  to  255  records.  If  this  count  has  exceeded,  the 
memory  is  considered as full. When the recording is in progress, the LED makes short flash 
each  2  seconds.  This  function  should  be  disabled  for  discrete  recording.  When  the  voice-
activated recording is enabled, the LED flashes only, when the sound level is above selected 
threshold  and  recording is in progress. The recording is stopped when the memory is full or 
by  pressing  the  operating  button.  3  LED  flashes  indicate  stop  sequence.  This  sequence  is 
followed after about one second, when you press operating button. To recognize clearly this 
state, this sequence of 3 flashes is followed during the time when you hold the button (when 
you  start  recording  by  using  the  button  LED  flash  sequence  starts  after  you  release  the 
button). 

 
Battery types 

 
For longest battery life in recording mode the Zinc-air batteries must be used. Recommended 
type us ZA675 or PR44. Optionally alkaline 1,5V batteries of the same size should be used, 
but the battery life will be shorter.  
 

Summary of Contents for TAR-22

Page 1: ...Tiny audio recorder TAR 22 User manual Version 1 16 ...

Page 2: ...erted and is ready for next action in about 5 seconds indicated by one single LED flash 4 For connecting recorder with PC you need to have record manager downloaded to your PC Recorder should be connected to PC only when it is in stand by mode otherwise you will get message USB device can t be detected Recorder should be connected to PC even without battery Powering TAR 22 via USB during recording...

Page 3: ...recording in any specific period of each day or at any specific date All recorded data are stored with time marks which gives you very good overview in case of long time recording Technical data Dimensions 46x9x16mm 1 65x0 35x0 63 Battery one single 1 5V Zinc Air ZA675 or AG13 Battery life in recording mode 85 hours with Zinc Air battery Memory capacity for recording 848 hours with 5 5kHz sample r...

Page 4: ...ng sequence will follow When it flashes only ones the memory is full and recording can t be started Flashing 2 to 4 times indicates available memory space 4 flashes more than 75 space available 3 flashes more than 50 space available 2 flashes less than 25 space available The recorder should store up to 255 records If this count has exceeded the memory is considered as full When the recording is in...

Page 5: ...ist To load each record double click on selected record you whish to load For using the detailed view you should select only specific area by using mouse left and right button and clicking on full record s overview window When the mouse is moved over this area the time is visible in bottom status bar This time scale should be non linear when the voice activated recording was used Recorder s settin...

Page 6: ... Next page is used for voice activated recording When this option is enabled recorder is recording only when it detects sound above selected threshold level Minimum level means the highest sensitivity Delay is specifying the time for how long recording continues after this sound level is not detected anymore Recommended value is 5 seconds or more When LED is enabled to flash during recording it is...

Page 7: ...very day Single timer is used to start and stop only once at given time and date The last is weekly timer where you can specify a different time periods for each day of a week Every time set to 00 00 is ignored which enables to schedule recording for example over the midnight The last part of a configuration contains various options Button function should be selected to double click or single clic...

Page 8: ... for export Long records should be split into more files Use option in menu Records Maximum size of exported file to specify maximum size of each exported WAV file FAQ Q Can t start recording LED flashes only once and the card is not full A The card contains 255 records For next recording you must delete at least last record from the list Q When the battery is inserted there is no LED indication a...